This topic details the slot distribution of the cards supported in TJ1600 Type-11SR, TJ1600 Type-6SR and TJ1600 Type-2SR systems.
NOTE: High power OFA (OFA-C-S26-FG/OFA-C-S23-FG), MDU-40E-C-100G and MDU-40O-C-100G, PSCM are standalone units and not installed on the chassis. Therefore, no slot numbers are assigned to these cards.
Card |
Configuration |
No. of Service Ports |
Slot number |
Support |
||
---|---|---|---|---|---|---|
|
|
|
|
XCC03 |
XCC04 |
OSMC |
HCPPFU02 |
-- |
|
12 and 13 |
Yes |
Yes |
Yes |
HCPFTU01 |
-- |
|
15 |
Yes |
Yes |
Yes |
HCPOAM01 |
-- |
|
14 |
Yes |
Yes |
Yes |
HCPSLine01 |
-- |
2xSTM-64/10GE |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
No |
HCPULine01 |
-- |
20xSTM-1/4 or 8xSTM-16 or 16x1GE ports (Except P5, P10, P15, P20) |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
No |
HCPSLine03 |
SDH Gateway Card |
4xSTM-64/10GE |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
No |
|
SDH FEC Card |
4xSTM-64 with FEC option. |
|
Yes |
Yes |
No |
|
OTN Flexi card |
4xSTM-64/10GE/OTU2/OTU2e |
|
No |
Yes |
No |
|
IntraCard TRANS/MUXPONDER |
4xSTM-64/10GE/OTU2/OTU2e |
|
Yes |
Yes |
Yes |
HCPSLine08 |
SDH Gateway Card |
P1 and P2: 2xSTM-64/10GE + P3 to P10: 8xSTM-16 or P3 to P18: 16xSTM-1/4/1GE |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
No |
|
OTN Flexi card |
P1 and P2: 2xSTM-64/10GE/OTU2/OTU2e + P3 to P10: 8xSTM-16/OTU1 or P3 to P18: 16xSTM-1/4/1GE |
|
No |
Yes |
No |
|
IntraCard TRANS/MUXPONDER |
P1 and P2: OTU2 + P3 to P10: 8xSTM-16/OTU1 or P3 to P18: 16xSTM-1/4/1GE |
|
Yes |
Yes |
Yes |
HCPSLine12 |
10X10 TO 1XOTU4 MUXPONDER |
P1: OTU4 + P4 to P13: STM-64/10GE/OTU2/OTU2e |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
HCPSLine20 |
SDH Only |
4xSTM-64/16/4/1 + 28xSTM-16/4/1 or 6xSTM-64/16/4/1 + 26xSTM-16/4/1 |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
No |
Yes |
No |
HCPSLine22 |
10x10G SDH Flexi |
10xSTM-64/10GE |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
No |
Yes |
No |
|
10X10G OTN TRIBUTARY |
|
|
No |
Yes |
No |
|
1x100G TRIBUTARY AND CROSS-CONNECT |
P11: 100GE/OTU4 |
|
No |
Yes |
No |
|
5 10G TRANSPONDER |
|
|
Yes |
Yes |
Yes |
|
10x10 TO 1XOTU4 MUXPONDER |
P1 to P10: STM-64/10GE/OTU2/OTU2e + P11: OTU4 |
|
Yes |
Yes |
Yes |
HCPSLine24 |
1X100G TRANSPONDER OTU4 NP |
P1: OTU4 + P4 : OTU4/100GE |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
HCPSLine25 |
10X10G TRANSPONDER |
|
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
HCPSLine28 |
1X100G TRANSPONDER OTU4 NP |
P1: OTU4 + P4 : OTU4/100GE |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
|
2X100G TRANSPONDER |
P1 and P4: OTU4 + P2 and P3: OTU4/100GE |
|
Yes |
Yes |
Yes |
CEF-5 |
2*10G + 12*1G (default mode) |
2x10GE + 12x1GE + 32VCG |
1, 2, 3, 4, 7, 8, 9, 10, 11 One mesh switch in either 2, 3, 4 or 8, 9, 10 |
Yes |
Yes |
Yes |
|
6*10G + 12*1G (License mode) |
6x10GE + 12x1GE + 32VCG |
Yes |
Yes |
Yes |
|
|
8*10G (License mode) |
8x10GE + 16VCG |
Yes |
Yes |
Yes |
|
NOTE 1: CEF-5 cards inserted in slots 1 will come up in standalone mode. If a mesh already exists in the system, then cards inserted in the other mesh slots will come up in standalone mode only. NOTE 2: In CEF-5 card, VCGs are supported in TJ1600 Type-11SR chassis when the Data Path Mode is selected as 'SDH'. VCGs are not supported on TJ1600 Type-11SR chassis with Data Path Mode as “OTN”. |
||||||
OFA |
-- |
Amplifier ports and Monitor ports. |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
ROADM-2-C-50G/ROADM-4-C-50G/ROADM-8-C-50G |
-- |
Dynamically add drop any wavelength up to 80 Channels. |
2, 3, 4, 8, 9, 10, 11 NOTE: ROADM-8-C-50G is a double slot card, hence this card cannot be installed on slot 1 and slot 7 of the chassis. |
Yes |
Yes |
Yes |
MDU-16CL-C-50G |
-- |
16-channel multiplexer and demultiplexer active optical card. |
2, 3, 4, 8, 9, 10, 11 NOTE: MDU-16CL-C-50G is a double slot card, hence this card cannot be installed on slot 1 and slot 7 of the chassis. |
Yes |
Yes |
Yes |
OPM-C-2 and OPM-C-4 |
-- |
OPM-C-4 is a 4 port and OPM-C-2 is a two port card which measure optical power from either 4 or 2 monitoring input ports. |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
HCPADP01 |
-- |
Accommodate both active cards and passive cards by dividing the slot into 2/3rd and 1/3rd slots; where 1/3rd supports FPU01, 2/3rd slot supports MDU-8-D card. |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
HCPADP02 |
-- |
Accommodate both active cards and passive cards by dividing a slot into two half slots; where 1/2nd slot supports VOA, ILU-C-50G, OADM1 and OADM4 cards. |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
VOA |
-- |
Supports eight ports in which eight hot pluggable VOA SFP modules can be inserted. |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
OFA-C-S26-FG/OFA-C-S23-FG |
-- |
Provides a high output power of up to 26/23dBm. |
-- |
Yes |
Yes |
Yes |
FPU01 |
-- |
Provides protection against the optical fiber line failures. |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
MDU-40E-C-100G and MDU-40O-C-100G |
-- |
100GHz channel with even spacing (192.00 to 195.90 THz) and with odd spacing (192.05 to 195.95 THz). |
-- |
Yes |
Yes |
Yes |
MDU-8-D |
-- |
Add and drop 8 DWDM channels with 100GHz spacing. |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
MDU-16-D |
-- |
Adds and drop 16 DWDM channels with 100GHz spacing |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
PSCM |
-- |
Splits the signal into N (N>1) parts in one direction and combines the N signals to produce one signal in other direction. |
-- |
Yes |
Yes |
Yes |
ILU-C-50G |
-- |
2 service ports, and each service port can cater to 40 channels. |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
OADM1 and OADM4 |
-- |
Adds and drops 1 and 4 channels at 100GHz spacing respectively. |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
Card |
Configuration |
No. of Service Ports |
Slot number |
|
---|---|---|---|---|
HCPPFU04 |
-- |
|
7 and 8 |
|
HCPFTU02 |
-- |
|
5 |
|
HCPOAM03 |
-- |
|
6 |
|
HCPSLine03 |
IntraCard TRANS/MUXPONDER |
4xSTM-64/10GE/OTU2/OTU2e |
1, 2, 3, 4 |
|
HCPSLine08 |
IntraCard TRANS/MUXPONDER |
P1 and P2: OTU2 + P3 to P10: 8xSTM-16/OTU1 or P3 to P18: 16xSTM-1/4/1GE |
1, 2, 3, 4 |
|
HCPSLine12 |
10X10 TO 1XOTU4 MUXPONDER |
P1: OTU4 + P4 to P13: STM-64/10GE/OTU2/OTU2e |
1, 2, 3, 4 |
|
HCPSLine22 |
5 10G TRANSPONDER |
|
1, 2, 3, 4 |
|
|
10x10 TO 1XOTU4 MUXPONDER |
P1 to P!0: STM-64/10GE/OTU2/OTU2e + P11: OTU4 muxponder |
|
|
|
10x10G FLEXI TRIBUTARY AND CROSS CONNECT (200GXC) |
|
1, 2 |
|
HCPSLine24 |
1X100G TRANSPONDER OTU4 NP |
P1: OTU4 + P4 : OTU4/100GE |
1, 2, 3, 4 |
|
HCPSLine25 |
10X10G TRANSPONDER |
|
1, 2, 3, 4 |
|
HCPSLine28 |
1X100G TRANSPONDER OTU4 NP |
1xOTU4 (P1) + 1xOTU4/100GE (P4) |
1, 2, 3, 4 |
|
|
2X100G TRANSPONDER |
2xOTU4 (P1 and P4) + 2xOTU4/100GE (P2 and P3) |
1, 2, 3, 4 |
|
CEF-5
|
2*10G + 12*1G (default mode) |
2x10GE + 12x1GE + 32VCG |
1, 2, 3, 4 One mesh switch in either 2, 3, 4 NOTE 1: Cards inserted in slots 1 will come up in standalone mode. If a mesh already exists in the system, then cards inserted in the other mesh slots will come up in standalone mode only. NOTE 2: VCG is not supported in this release. |
|
6*10G + 12*1G (License mode) |
6x10GE + 12x1GE + 32VCG |
|||
8*10G (License mode) |
8x10GE + 16VCG
|
|||
|
||||
OFA |
-- |
Amplifier ports and Monitor ports. |
1, 2, 3, 4 |
|
ROADM-2-C-50G/ROADM-4-C-50G/ROADM-8-C-50G |
-- |
Dynamically add drop any wavelength up to 80 Channels. |
2, 3, 4 NOTE: ROADM-8-C-50G is a double slot card, hence this card cannot be installed on slot 1 of the chassis. |
|
MDU-16CL-C-50G |
-- |
16-channel multiplexer and demultiplexer active optical card. |
2, 3, 4 NOTE: MDU-16CL-C-50G is a double slot card, hence this card cannot be installed on slot 1 of the chassis. |
|
OPM-C-2 and OPM-C-4 |
-- |
OPM-C-4 is a 4 port and OPM-C-2 is a two port card which measure optical power from either 4 or 2 monitoring input ports. |
1, 2, 3, 4 |
|
HCPADP01 |
-- |
Accommodate both active cards and passive cards by dividing the slot into 2/3rd and 1/3rd slots; where 1/3rd supports FPU01, 2/3rd slot supports MDU-8-D card. |
1, 2, 3, 4 |
|
HCPADP02 |
-- |
Accommodate both active cards and passive cards by dividing a slot into two half slots; where 1/2nd slot supports VOA, ILU-C-50G, OADM1 and OADM4 cards. |
1, 2, 3, 4 |
|
VOA |
-- |
Supports eight ports in which eight hot pluggable VOA SFP modules can be inserted. |
1, 2, 3, 4 |
|
OFA-C-S26-FG/OFA-C-S23-FG |
-- |
Provides a high output power of up to 26/23dBm. |
-- |
|
FPU01 |
-- |
Provides protection against the optical fiber line failures. |
1, 2, 3, 4 |
|
MDU-40E-C-100G and MDU-40O-C-100G |
-- |
100GHz channel with even spacing (192.00 to 195.90 THz) and with odd spacing (192.05 to 195.95 THz). |
-- |
|
MDU-8-D |
-- |
Add and drop 8 DWDM channels with 100GHz spacing. |
1, 2, 3, 4 |
|
MDU-16-D |
-- |
Adds and drop 16 DWDM channels with 100GHz spacing |
1, 2, 3, 4 |
|
PSCM |
-- |
Splits the signal into N (N>1) parts in one direction and combines the N signals to produce one signal in other direction. |
-- |
|
ILU-C-50G |
-- |
2 service ports, and each service port can cater to 40 channels. |
1, 2, 3, 4 |
|
OADM1 and OADM4 |
-- |
Adds and drops 1 and 4 channels at 100GHz spacing respectively. |
1, 2, 3, 4 |
Card |
Configuration |
No. of Service Ports |
Slot number |
---|---|---|---|
HCPPFU05 |
-- |
|
3 and 4 |
FTU |
-- |
|
6 |
OAMC |
-- |
|
5 |
HCPSLine03 |
IntraCard TRANS/MUXPONDER |
4xSTM-64/10GE/OTU2/OTU2e |
1, 2 |
HCPSLine08 |
IntraCard TRANS/MUXPONDER |
P1 and P2: OTU2 + P3 to P10: 8xSTM-16/OTU1 or P3 to P18: 16xSTM-1/4/1GE |
1, 2 |
HCPSLine12 |
10X10 TO 1XOTU4 MUXPONDER |
P1: OTU4 + P4 to P13: STM-64/10GE/OTU2/OTU2e |
1, 2 |
HCPSLine22 |
10x10G FLEXI TRIBUTARY AND CROSS CONNECT (200GXC) |
|
1, 2 |
HCPSLine24 |
1X100G TRANSPONDER OTU4 NP |
P1: OTU4 + P4 : OTU4/100GE |
1, 2 |
HCPSLine25 |
10X10G TRANSPONDER |
|
1, 2 |
HCPSLine28 |
1X100G TRANSPONDER OTU4 NP |
1xOTU4 (P1) + 1xOTU4/100GE (P4) |
1, 2 |
|
2X100G TRANSPONDER |
2xOTU4 (P1 and P4) + 2xOTU4/100GE (P2 and P3) |
|
OFA |
-- |
Amplifier ports and Monitor ports. |
1, 2 |
OPM-C-2 and OPM-C-4 |
-- |
OPM-C-4 is a 4 port and OPM-C-2 is a two port card which measure optical power from either 4 or 2 monitoring input ports. |
1, 2 |
HCPADP01 |
-- |
Accommodate both active cards and passive cards by dividing the slot into 2/3rd and 1/3rd slots; where 1/3rd supports FPU01, 2/3rd slot supports MDU-8-D card. |
1, 2 |
HCPADP02 |
-- |
Accommodate both active cards and passive cards by dividing a slot into two half slots; where 1/2nd slot supports VOA, ILU-C-50G, OADM1 and OADM4 cards. |
1, 2 |
VOA |
-- |
Supports eight ports in which eight hot pluggable VOA SFP modules can be inserted. |
1, 2 |
OFA-C-S26-FG/OFA-C-S23-FG |
-- |
Provides a high output power of up to 26/23dBm. |
-- |
FPU01 |
-- |
Provides protection against the optical fiber line failures. |
1, 2 |
MDU-40E-C-100G and MDU-40O-C-100G |
-- |
100GHz channel with even spacing (192.00 to 195.90 THz) and with odd spacing (192.05 to 195.95 THz). |
-- |
MDU-8-D |
-- |
Add and drop 8 DWDM channels with 100GHz spacing. |
1, 2 |
MDU-16-D |
-- |
Adds and drop 16 DWDM channels with 100GHz spacing |
1, 2 |
PSCM |
-- |
Splits the signal into N (N>1) parts in one direction and combines the N signals to produce one signal in other direction. |
-- |
ILU-C-50G |
-- |
2 service ports, and each service port can cater to 40 channels. |
1, 2 |
OADM1 and OADM4 |
-- |
Adds and drops 1 and 4 channels at 100GHz spacing respectively. |
1, 2 |