Previous Topic

Next Topic

Book Contents

Slot distribution

This topic details the slot distribution of the cards supported in TJ1600 Type-11SR, TJ1600 Type-6SR and TJ1600 Type-2SR systems.

NOTE: High power OFA (OFA-C-S26-FG/OFA-C-S23-FG), MDU-40E-C-100G and MDU-40O-C-100G, PSCM are standalone units and not installed on the chassis. Therefore, no slot numbers are assigned to these cards.

Slot distribution of TJ1600 Type-11SR with HCPXCC03, HCPXCC04 and OSMC01 cards

Card

Configuration

No. of Service Ports

Slot number

Support

 

 

 

 

XCC03

XCC04

OSMC

HCPPFU02

--

 

12 and 13

Yes

Yes

Yes

HCPFTU01

--

 

15

Yes

Yes

Yes

HCPOAM01

--

 

14

Yes

Yes

Yes

HCPSLine01

--

2xSTM-64/10GE

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

No

HCPULine01

--

20xSTM-1/4 or 8xSTM-16 or 16x1GE ports (Except P5, P10, P15, P20)

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

No

HCPSLine03

SDH Gateway Card

4xSTM-64/10GE

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

No

 

SDH FEC Card

4xSTM-64 with FEC option.

 

Yes

Yes

No

 

OTN Flexi card

4xSTM-64/10GE/OTU2/OTU2e

 

No

Yes

No

 

IntraCard TRANS/MUXPONDER

4xSTM-64/10GE/OTU2/OTU2e

 

Yes

Yes

Yes

HCPSLine08

SDH Gateway Card

P1 and P2: 2xSTM-64/10GE + P3 to P10: 8xSTM-16 or P3 to P18: 16xSTM-1/4/1GE

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

No

 

OTN Flexi card

P1 and P2: 2xSTM-64/10GE/OTU2/OTU2e + P3 to P10: 8xSTM-16/OTU1 or P3 to P18: 16xSTM-1/4/1GE

 

No

Yes

No

 

IntraCard TRANS/MUXPONDER

P1 and P2: OTU2 + P3 to P10: 8xSTM-16/OTU1 or P3 to P18: 16xSTM-1/4/1GE

 

Yes

Yes

Yes

HCPSLine12

10X10 TO 1XOTU4 MUXPONDER

P1: OTU4 + P4 to P13: STM-64/10GE/OTU2/OTU2e

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

HCPSLine20

SDH Only

4xSTM-64/16/4/1 + 28xSTM-16/4/1 or 6xSTM-64/16/4/1 + 26xSTM-16/4/1

1, 2, 3, 4, 7, 8, 9, 10, 11

No

Yes

No

HCPSLine22

10x10G SDH Flexi

10xSTM-64/10GE

1, 2, 3, 4, 7, 8, 9, 10, 11

No

Yes

No

 

10X10G OTN TRIBUTARY

  • P1 to P10: 10xSTM-64/10GE LAN/OTU2/OTU2e/8GFC
  • OTU2/OTU2e ports (P1, P2, P7 and P9) support ODUj channelization.
  • 10GE port support GFP mapping and ODUflex (P3 and P10)

 

No

Yes

No

 

1x100G TRIBUTARY AND CROSS-CONNECT

P11: 100GE/OTU4

 

No

Yes

No

 

5 10G TRANSPONDER

  • P1 to P5: OTU2/OTU2e
  • P6 to P10: STM-64/10GE/OTU2/OTU2e/OTU1f/8GFC/12GFC

 

Yes

Yes

Yes

 

10x10 TO 1XOTU4 MUXPONDER

P1 to P10: STM-64/10GE/OTU2/OTU2e + P11:

OTU4

 

Yes

Yes

Yes

HCPSLine24

1X100G TRANSPONDER OTU4 NP

P1: OTU4 + P4 : OTU4/100GE

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

HCPSLine25

10X10G TRANSPONDER

  • P1 to P10: OTU2/OTU2e
  • P11 to P20: STM-64/10GE/OTU2/OTU2e

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

HCPSLine28

1X100G TRANSPONDER OTU4 NP

P1: OTU4 + P4 : OTU4/100GE

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

 

2X100G TRANSPONDER

P1 and P4: OTU4 + P2 and P3: OTU4/100GE

 

Yes

Yes

Yes

CEF-5

2*10G + 12*1G (default mode)

2x10GE + 12x1GE + 32VCG

1, 2, 3, 4, 7, 8, 9, 10, 11 One mesh switch in either 2, 3, 4 or 8, 9, 10

Yes

Yes

Yes

 

6*10G + 12*1G (License mode)

6x10GE + 12x1GE + 32VCG

Yes

Yes

Yes

 

8*10G (License mode)

8x10GE + 16VCG

Yes

Yes

Yes

NOTE 1: CEF-5 cards inserted in slots 1 will come up in standalone mode. If a mesh already exists in the system, then cards inserted in the other mesh slots will come up in standalone mode only.

NOTE 2: In CEF-5 card, VCGs are supported in TJ1600 Type-11SR chassis when the Data Path Mode is selected as 'SDH'. VCGs are not supported on TJ1600 Type-11SR chassis with Data Path Mode as “OTN”.

OFA

--

Amplifier ports and Monitor ports.

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

ROADM-2-C-50G/ROADM-4-C-50G/ROADM-8-C-50G

--

Dynamically add drop any wavelength up to 80 Channels.

2, 3, 4, 8, 9, 10, 11

NOTE: ROADM-8-C-50G is a double slot card, hence this card cannot be installed on slot 1 and slot 7 of the chassis.

Yes

Yes

Yes

MDU-16CL-C-50G

--

16-channel multiplexer and demultiplexer active optical card.

2, 3, 4, 8, 9, 10, 11

NOTE: MDU-16CL-C-50G is a double slot card, hence this card cannot be installed on slot 1 and slot 7 of the chassis.

Yes

Yes

Yes

OPM-C-2 and OPM-C-4

--

OPM-C-4 is a 4 port and OPM-C-2 is a two port card which measure optical power from either 4 or 2 monitoring input ports.

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

HCPADP01

--

Accommodate both active cards and passive cards by dividing the slot into 2/3rd and 1/3rd slots; where 1/3rd supports FPU01, 2/3rd slot supports MDU-8-D card.

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

HCPADP02

--

Accommodate both active cards and passive cards by dividing a slot into two half slots; where 1/2nd slot supports VOA, ILU-C-50G, OADM1 and OADM4 cards.

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

VOA

--

Supports eight ports in which eight hot pluggable VOA SFP modules can be inserted.

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

OFA-C-S26-FG/OFA-C-S23-FG

--

Provides a high output power of up to 26/23dBm.

--

Yes

Yes

Yes

FPU01

--

Provides protection against the optical fiber line failures.

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

MDU-40E-C-100G and MDU-40O-C-100G

--

100GHz channel with even spacing (192.00 to 195.90 THz) and with odd spacing (192.05 to 195.95 THz).

--

Yes

Yes

Yes

MDU-8-D

--

Add and drop 8 DWDM channels with 100GHz spacing.

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

MDU-16-D

--

Adds and drop 16 DWDM channels with 100GHz spacing

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

PSCM

--

Splits the signal into N (N>1) parts in one direction and combines the N signals to produce one signal in other direction.

--

Yes

Yes

Yes

ILU-C-50G

--

2 service ports, and each service port can cater to 40 channels.

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

OADM1 and OADM4

--

Adds and drops 1 and 4 channels at 100GHz spacing respectively.

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

Slot distribution of TJ1600 Type-6SR with OSMC01 card

Card

Configuration

No. of Service Ports

Slot number

HCPPFU04

--

 

7 and 8

HCPFTU02

--

 

5

HCPOAM03

--

 

6

HCPSLine03

IntraCard TRANS/MUXPONDER

4xSTM-64/10GE/OTU2/OTU2e

1, 2, 3, 4

HCPSLine08

IntraCard TRANS/MUXPONDER

P1 and P2: OTU2 + P3 to P10: 8xSTM-16/OTU1 or P3 to P18: 16xSTM-1/4/1GE

1, 2, 3, 4

HCPSLine12

10X10 TO 1XOTU4 MUXPONDER

P1: OTU4 + P4 to P13: STM-64/10GE/OTU2/OTU2e

1, 2, 3, 4

HCPSLine22

5 10G TRANSPONDER

  • P1 to P5: 5xOTU2/OTU2e
  • P6 to P10: 5xSTM-64/10GE/OTU2/OTU2e/OTU1f/8GFC/12GFC

1, 2, 3, 4

 

10x10 TO 1XOTU4 MUXPONDER

P1 to P!0: STM-64/10GE/OTU2/OTU2e +

P11: OTU4 muxponder

 

 

10x10G FLEXI TRIBUTARY AND CROSS CONNECT (200GXC)

  • P1-P10: STM-1/4/16/STM64/1GE/10GE/1GFC/2GFC/8GFC
  • P1, P2, P7, P9: OTU2/OTU2e
  • 10GE port support GFP mapping and ODUflex (P3 & P10)

1, 2

HCPSLine24

1X100G TRANSPONDER OTU4 NP

P1: OTU4 + P4 : OTU4/100GE

1, 2, 3, 4

HCPSLine25

10X10G TRANSPONDER

  • P1 to P10: OTU2/OTU2e
  • P11 to P20: STM-64/10GE/OTU2/OTU2e

1, 2, 3, 4

HCPSLine28

1X100G TRANSPONDER OTU4 NP

1xOTU4 (P1) + 1xOTU4/100GE (P4)

1, 2, 3, 4

 

2X100G TRANSPONDER

2xOTU4 (P1 and P4) + 2xOTU4/100GE (P2 and P3)

1, 2, 3, 4

CEF-5

 

2*10G + 12*1G (default mode)

2x10GE + 12x1GE + 32VCG

1, 2, 3, 4

One mesh switch in either 2, 3, 4

NOTE 1: Cards inserted in slots 1 will come up in standalone mode. If a mesh already exists in the system, then cards inserted in the other mesh slots will come up in standalone mode only.

NOTE 2: VCG is not supported in this release.

6*10G + 12*1G (License mode)

6x10GE + 12x1GE + 32VCG

8*10G (License mode)

8x10GE + 16VCG

 

 

OFA

--

Amplifier ports and Monitor ports.

1, 2, 3, 4

ROADM-2-C-50G/ROADM-4-C-50G/ROADM-8-C-50G

--

Dynamically add drop any wavelength up to 80 Channels.

2, 3, 4

NOTE: ROADM-8-C-50G is a double slot card, hence this card cannot be installed on slot 1 of the chassis.

MDU-16CL-C-50G

--

16-channel multiplexer and demultiplexer active optical card.

2, 3, 4

NOTE: MDU-16CL-C-50G is a double slot card, hence this card cannot be installed on slot 1 of the chassis.

OPM-C-2 and OPM-C-4

--

OPM-C-4 is a 4 port and OPM-C-2 is a two port card which measure optical power from either 4 or 2 monitoring input ports.

1, 2, 3, 4

HCPADP01

--

Accommodate both active cards and passive cards by dividing the slot into 2/3rd and 1/3rd slots; where 1/3rd supports FPU01, 2/3rd slot supports MDU-8-D card.

1, 2, 3, 4

HCPADP02

--

Accommodate both active cards and passive cards by dividing a slot into two half slots; where 1/2nd slot supports VOA, ILU-C-50G, OADM1 and OADM4 cards.

1, 2, 3, 4

VOA

--

Supports eight ports in which eight hot pluggable VOA SFP modules can be inserted.

1, 2, 3, 4

OFA-C-S26-FG/OFA-C-S23-FG

--

Provides a high output power of up to 26/23dBm.

--

FPU01

--

Provides protection against the optical fiber line failures.

1, 2, 3, 4

MDU-40E-C-100G and MDU-40O-C-100G

--

100GHz channel with even spacing (192.00 to 195.90 THz) and with odd spacing (192.05 to 195.95 THz).

--

MDU-8-D

--

Add and drop 8 DWDM channels with 100GHz spacing.

1, 2, 3, 4

MDU-16-D

--

Adds and drop 16 DWDM channels with 100GHz spacing

1, 2, 3, 4

PSCM

--

Splits the signal into N (N>1) parts in one direction and combines the N signals to produce one signal in other direction.

--

ILU-C-50G

--

2 service ports, and each service port can cater to 40 channels.

1, 2, 3, 4

OADM1 and OADM4

--

Adds and drops 1 and 4 channels at 100GHz spacing respectively.

1, 2, 3, 4

Slot distribution of TJ1600 Type-2SR with OAMC card

Card

Configuration

No. of Service Ports

Slot number

HCPPFU05

--

 

3 and 4

FTU

--

 

6

OAMC

--

 

5

HCPSLine03

IntraCard TRANS/MUXPONDER

4xSTM-64/10GE/OTU2/OTU2e

1, 2

HCPSLine08

IntraCard TRANS/MUXPONDER

P1 and P2: OTU2 + P3 to P10: 8xSTM-16/OTU1 or P3 to P18: 16xSTM-1/4/1GE

1, 2

HCPSLine12

10X10 TO 1XOTU4 MUXPONDER

P1: OTU4 + P4 to P13: STM-64/10GE/OTU2/OTU2e

1, 2

HCPSLine22

10x10G FLEXI TRIBUTARY AND CROSS CONNECT (200GXC)

  • P1-P10: STM-1/4/16/STM64/1GE/10GE/1GFC/2GFC/8GFC
  • P1, P2, P7, P9: OTU2/OTU2e
  • 10GE port support GFP mapping and ODUflex (P3 & P10)

1, 2

HCPSLine24

1X100G TRANSPONDER OTU4 NP

P1: OTU4 + P4 : OTU4/100GE

1, 2

HCPSLine25

10X10G TRANSPONDER

  • P1 to P10: OTU2/OTU2e
  • P11 to P20: STM-64/10GE/OTU2/OTU2e

1, 2

HCPSLine28

1X100G TRANSPONDER OTU4 NP

1xOTU4 (P1) + 1xOTU4/100GE (P4)

1, 2

 

2X100G TRANSPONDER

2xOTU4 (P1 and P4) + 2xOTU4/100GE (P2 and P3)

 

OFA

--

Amplifier ports and Monitor ports.

1, 2

OPM-C-2 and OPM-C-4

--

OPM-C-4 is a 4 port and OPM-C-2 is a two port card which measure optical power from either 4 or 2 monitoring input ports.

1, 2

HCPADP01

--

Accommodate both active cards and passive cards by dividing the slot into 2/3rd and 1/3rd slots; where 1/3rd supports FPU01, 2/3rd slot supports MDU-8-D card.

1, 2

HCPADP02

--

Accommodate both active cards and passive cards by dividing a slot into two half slots; where 1/2nd slot supports VOA, ILU-C-50G, OADM1 and OADM4 cards.

1, 2

VOA

--

Supports eight ports in which eight hot pluggable VOA SFP modules can be inserted.

1, 2

OFA-C-S26-FG/OFA-C-S23-FG

--

Provides a high output power of up to 26/23dBm.

--

FPU01

--

Provides protection against the optical fiber line failures.

1, 2

MDU-40E-C-100G and MDU-40O-C-100G

--

100GHz channel with even spacing (192.00 to 195.90 THz) and with odd spacing (192.05 to 195.95 THz).

--

MDU-8-D

--

Add and drop 8 DWDM channels with 100GHz spacing.

1, 2

MDU-16-D

--

Adds and drop 16 DWDM channels with 100GHz spacing

1, 2

PSCM

--

Splits the signal into N (N>1) parts in one direction and combines the N signals to produce one signal in other direction.

--

ILU-C-50G

--

2 service ports, and each service port can cater to 40 channels.

1, 2

OADM1 and OADM4

--

Adds and drops 1 and 4 channels at 100GHz spacing respectively.

1, 2

See also

Card population rule

Slot allotment

Using the Filler Panels