The Power Filter Unit (HCPPFU05) is used in TJ1600 Type-2SR chassis to supply power. The unit provides a filtered input voltage of -40V to -57.6V to the chassis and the cards on the chassis.

There are two HCPPFU05 cards in each system to provide input source redundancy. An EMI filter is used to restrict conducted emissions. The filters have transient voltage suppressors to prevent voltage surges affecting the system.

Static Discharge WarningSTATIC DISCHARGE WARNING: Static charge can damage the equipment. While handling cards for making system interconnections, wear an ESD strap to discharge the static buildup.

Caution Sign CAUTION: This equipment might have more than one power supply connection. All connection must be removed to de-energize the unit before accessing internal parts for maintenance or service.

Danger Warning DANGER: Do not jack-in/jack-out PFU card in the system with Power Cable connected. PFU has high energy and/or voltage level that can cause serious electrocution or burn.

Front panel

Following figure shows the front panel diagram of the HCPPFU05:

TJ1600-2 PFU - Front panel

Operational specifications

Operational specifications of Power Filter Unit- HCPPFU05

Specification

Range

Input Voltage Range

-40V to -57.6V DC

Reverse Polarity Protection

Continuous

Input Current

11A continuous at nominal voltage, 12.5A maximum at -40V during normal operation.

Maximum operating Ambient Temperature

-5°C to 55°C

Output Voltage

-40V to -57.6V DC

Output Current

8.68A (min) to 12.5A (min) from 40V to 57.6V, maximum power of 500W at any input voltage.

Efficiency

>99% Load when input is -48V DC

Fuse

20A Telecom fuse

Under Voltage Protection

  • Shutdown: -34V ± 2V
  • Recovery: -38V ± 2V

Hold-up Time (Interruption)

0.5ms at 53.5V and above.

Power Interface

  • Input: One 3-pin Power Header
  • Output: One FCI Connector

Protections

  • Over Voltage
  • Under Voltage
  • Over Current

Status Indication

Power LED: Indicates presence of Output voltage (Green)

Over Voltage Protection

  • Shutdown: -61V ± 2V
  • Recovery: -58V ± 2V

Functional description

Following are the functional features of the HCPPFU05:

See also

Power Filter Units

HCPPFU02

HCPPFU04