Previous Topic

Next Topic

Book Contents

Book Index

Card population rule

The following card population table summarizes the various cards/modules and the slot distribution for the TJ1600 product family.

Card population rule

Tributary Card/Controller Card

Card Population

TJ1600-2

(OAMC)

TJ1600-6

(OSMC01)

TJ1600-11

OSMC01

HCPXCC03

HCPXCC04

OAMC

5

NA

NA

NA

NA

OSMC01

NA

9, 10

5, 6

NA

NA

HCPXCC03

NA

NA

NA

5,6

NA

HCPXCC04

NA

NA

NA

NA

5, 6

HCPSLine01

NA

NA

NA

1 to 4 and 7 to 11

1 to 4 and 7 to 11

HCPULine01

NA

NA

NA

1 to 4 and 7 to 11

1 to 4 and 7 to 11

HCPSLine03

1, 2

1 to 4

1 to 4 and 7 to 11

1 to 4 and 7 to 11

1 to 4 and 7 to 11

HCPSLine08

1, 2

1 to 4

1 to 4 and 7 to 11

1 to 4 and 7 to 11

1 to 4 and 7 to 11

HCPSLine12

1, 2

1 to 4

1 to 4 and 7 to 11

1 to 4 and 7 to 11

1 to 4 and 7 to 11

HCPSLine20

NA

NA

NA

NA

1 to 4 and 7 to 11

HCPSLine22

1, 2

1 to 4

1 to 4 and 7 to 11

1 to 4 and 7 to 11

1 to 4 and 7 to 11

HCPSLine24

1, 2

1 to 4

1 to 4 and 7 to 11

1 to 4 and 7 to 11

1 to 4 and 7 to 11

HCPSLine25

1, 2

1 to 4

1 to 4 and 7 to 11

1 to 4 and 7 to 11

1 to 4 and 7 to 11

HCPSLine26

1, 2

1 to 4

1 to 3 and 7 to 10

1 to 4 and 7 to 11

1 to 4 and 7 to 11

HCPSLine27

1, 2

1 to 4

1 to 3 and 7 to 10

1 to 4 and 7 to 11

1 to 4 and 7 to 11

HCPSLine28

1,2

1 to 4

1 to 4 and 7 to 11

1 to 4 and 7 to 11

1 to 4 and 7 to 11

CEF-5

NA

2 to 4

1 to 4 and 7 to 11

(One mesh switch in either 2, 3, 4 or 8, 9, 10)

1 to 4 and 7 to 11

(One mesh switch in either 2, 3, 4 or 8, 9, 10)

1 to 4 and 7 to 11

(One mesh switch in either 2, 3, 4 or 8, 9, 10)

DWDM Cards

OFA

1, 2

1 to 4

1 to 4 and 7 to 11

1 to 4 and 7 to 11

1 to 4 and 7 to 11

ROADM-2-C-50G

1,2

1 to 4

1 to 4 and 7 to 11

1 to 4 and 7 to 11

1 to 4 and 7 to 11

ROADM-4-C-50G

1,2

1 to 4

1 to 4 and 7 to 11

1 to 4 and 7 to 11

1 to 4 and 7 to 11

ROADM-8-C-50G

2

2 to 4

2 to 4 and 8 to 11

2 to 4 and 8 to 11

2 to 4 and 8 to 11

OPM-C-2/OPM-C-4/OPM-C-FLEX

1, 2

1 to 4

1 to 4 and 7 to 11

1 to 4 and 7 to 11

1 to 4 and 7 to 11

FPU01/FPU02

1, 2

1 to 4

1 to 4 and 7 to 11

1 to 4 and 7 to 11

1 to 4 and 7 to 11

VOA

1, 2

1 to 4

1 to 4 and 7 to 11

1 to 4 and 7 to 11

1 to 4 and 7 to 11

OADM-1-D and OADM-4-D

1, 2

1 to 4

1 to 4 and 7 to 11

1 to 4 and 7 to 11

1 to 4 and 7 to 11

MDU-8-D

1, 2

1 to 4

1 to 4 and 7 to 11

1 to 4 and 7 to 11

1 to 4 and 7 to 11

MDU-16-D

1, 2

1 to 4

1 to 4 and 7 to 11

1 to 4 and 7 to 11

1 to 4 and 7 to 11

MDU-16CL-C-50G

2

2 to 4

2 to 4 and 8 to 11

2 to 4 and 8 to 11

2 to 4 and 8 to 11

ILU-C-50G

1, 2

1 to 4

1 to 4 and 7 to 11

1 to 4 and 7 to 11

1 to 4 and 7 to 11

ILU-C-100G

1, 2

1 to 4

1 to 4 and 7 to 11

1 to 4 and 7 to 11

1 to 4 and 7 to 11

HCPADP01

2

1 to 4

1 to 4 and 7 to 11

1 t 4 and 7 to 11

1 to 4 and 7 to 11

HCPADP02

2

1 to 4

1 to 4 and 7 to 11

1 to 4 and 7 to 11

1 to 4 and 7 to 11

NOTE: PSCM, DCM, OFA-C-S26-FG/OFA-C-S23-FG, ORA, MDU40E-D, MDU40O-D, MDU-40E-C-100G, MDU-40O-C-100G, add MDU-96-C-50G are standalone units and not installed on the chassis. Therefore, no slot numbers mentioned for these cards.

OSCF-S and OSCF-D modules are plugged into the OFA card. Therefore no slot numbers mentioned for these cards.