Two 40G/OTU3 optical ports, and one pluggable 100G/OTU4 optical port. It supports a maximum of 100G SDH/OTN backhaul. The card can be configured as transponder (at 10G) and muxponder (at 100G line side) card. The 100G port P1 supports 100G Coherent DWDM CFP and non-coherent CFP. The 40G ports P2 and P3 are of QSFP+ types. The 10G ports P4 to P13 are of SFP+ types. This card is supported in TJ1600 Type-11SR, TJ1600 Type-6SR and TJ1600 Type-2SR chassis.
HCPSLine12 card supports CFP (P1), 2xQSFP+ (P2 and P3), 10xSFP+ (P4 to P13) interfaces.
The mode(s) supported with OSMC01, HCPXCC03, HCPXCC04 and OAMC include:
NOTE 1: The 40G/OTU3 ports P2 and P3 are not supported in this product release.
NOTE 2: HCPSLine12 card can only be configured in muxponder mode in this product release. On the Node WUI, the card can be configured in 10x10G TO 1xOTU4 MUXPONDER mode.
Following is a schematic of the traffic configuration with POTP configuration:
The HCPSLine12 card also supports 10G and 40G Client to 1xOTU4 muxponder configurations as described earlier. The client side supports SFP+/QSFP+ optical interface and the line/network side supports CFP.
Following functionalities in particular are supported:
Following is a schematic of the traffic configuration in DWDM configuration:
Following figure shows the front panel view of HCPSLine12 card:
Specification |
Range |
---|---|
Input Voltage |
-48V DC |
Maximum Power consumption |
120W |
The visual indicators on the HCPSLine12 card include two LEDs, the Active and the Status LEDs.
Card State |
Status LED |
Active LED |
---|---|---|
Card initialization: State before the card initialize is complete on card insertion |
Amber (Steady) |
Amber (Steady) |
Card in service: Initialization complete and card in service |
Green (Steady) |
Green (Steady) |
Card mis-match: Network Element has already configured the slot with some other card |
Amber |
Amber |
Card failed during boot up |
Red |
Amber |
Card failed while in-service |
Red |
Green |
Improper jack in of the card |
Green (Blinking) |
Green (Blinking) |
Hard Reset: All devices reset, FPGAs cleared and reprogrammed. Goes to initializing state next |
Amber |
Amber |
Soft Reset: Software is restarted, devices are reinitialized with provisioning. Goes to initializing state next |
Green |
Green |
State |
Rx LED |
Tx LED |
---|---|---|
CFP present (Laser on) with Rx LOS |
Amber |
Green |
CFP present (Laser off) with Rx LOS |
Amber |
Off |
CFP present (Laser on) with no Rx LOS |
Green |
Green |
CFP present (Laser off) with no Rx LOS |
Green |
Off |
Card failed while in-service |
Red |
Green |
CFP missing (LOS detected), Laser On (attempted) |
Amber |
Green |
CFP missing (LOS masked since XFP missing and set to Admin_down), Laser Off (attempted) |
Amber |
Off |
CFP failed (whether provisioned, unprovisioned, LOS or no LOS) |
Red |
Red |
State |
Rx LED |
Tx LED |
---|---|---|
SFP+/QSFP+ present (Laser on) with Rx LOS |
Amber |
Green |
SFP+/QSFP+ present (Laser off) with Rx LOS |
Amber |
Off |
SFP+/QSFP+ present (Laser on) with no Rx LOS |
Green |
Green |
SFP+/QSFP+ present (Laser off) with no Rx LOS |
Green |
Off |
Card failed while in-service |
Red |
Green |
SFP+/QSFP+ missing (LOS detected), Laser On (attempted) |
Amber |
Green |
SFP+/QSFP+ missing (LOS masked since SFP missing and set to Admin_down), Laser Off (attempted) |
Amber |
Off |
SFP+/QSFP+ failed (whether provisioned, unprovisioned, LOS or no LOS) |
Red |
Red |
Optics |
Rate |
Reach (Km)* |
---|---|---|
10GE SFP+ |
10Gbps |
10 km |
S64.2b SFP+ |
STM-64 |
40 km |
P1L1-2D2 SFP+ |
STM-64/OTU2 |
80 km |
DWDM Fixed/Tunable SFP+ |
10Gbps/STM-64/OTU2 |
80 km |
QSFP+ |
40GE/OTU3 |
10 km |
CFP |
100GBASE-SR10/OTU4 |
100m |
CFP |
100GBASE-LR4/OTU4 |
10 km |
CFP |
100GBASE-ER4/OTU4 |
40 km |
CFP Coherent |
100GE/OTU4 |
80 km |
CFP Coherent |
100GE/OTU4 |
~1000 km (amplified) |
* For G.652 fiber under Standard link conditions |
HCPSLine12 card supports the following functional features: