Type |
Parameter |
Value |
|
---|---|---|---|
Installation Rack |
Installation rack type (in inch) |
19" |
|
Chassis installation rack height (RU) |
4U (176 mm) |
||
Air flow direction in the chassis |
Right to Left |
||
Mechanical Specifications
|
Height |
176 mm |
|
Width |
With Mount angles |
483 mm |
|
Without Mount angles |
440 mm |
||
Depth |
Excluding Air Filter latch handle |
258 mm |
|
Weight |
Chassis with Mount angles, Backplane, and Air Filter Unit |
6 KG |
|
Electrical Specifications
|
Power Consumption |
1000W |
|
Input Voltage range |
40V to 60V |
||
Environmental Specifications
|
Operating temperature range |
0 °C to 40 °C below 0 °C is permissible and above 40 °C is permissible with probability less than 1%. |
|
Relative humidity |
95% RH |
NOTE: If the HCPSLine26 and HCPSLine27 cards are used in the system then the system operating temperature range is derated to support from 0 °C to 40 °C.
A temperature of 50°C or -5°C is permissible but should not exceed the following:
- Duration: 96 continuous hours.
- Days: 15 days in one year.
- Occurrences: 15 times during a one-year period.