Executing External Command on a Synchronization Source

Perform the steps given below to execute external command on a synchronization source.

  1. Click Protection > Timing manager in the navigation pane. The Timing manager protection request preview pane is displayed.
  2. Under the Select field, select the check box for the Clock source on which the command is to be issued.
  3. To issue an external command, click on the desired command button. Timing manager protection request confirm preview pane is displayed. For more information, refer to External Commands table given below.
  4. Click Confirm Request. The command is successfully issued on the clock source.

External Commands

Parameter

Description

Release

Clears the previous external requests.

Forced Switch

The node switches to the selected clock source on an external request for forced switch. The node cannot be switched to other clock sources unless the external request is cleared. Forced switch has a higher priority over manual switch.

Manual Switch

The node explicitly force the SSM module to latch onto a higher quality/priority reference clock. This command cannot be issued if there is a lockout on the clock, or if the clock is in a signal fail state.

Lockout Source

This excludes the particular timing source from being considered for selection as a clock reference.

Clear Lockout

Clears the lock on the clock source so that the node can be synchronized to the clock source.