Perform the steps given below to provision a new path alarm profile.
Parameter
|
Description
|
Default Value
|
Acceptable Value
|
Profile Name
|
Allows you to enter a name for new path alarm profile.
|
--
|
Includes a set of alphanumeric characters
|
TIM Action
|
Allows you to select the TIM action.
- Ignore TIM: No action on trace identifier mismatch.
- Report TIM, No Downstream AIS: It reports TIM on trace identifier mismatch, does not send downstream AIS.
- Downstream AIS on TIM: It sends Downstream alarm indication signal (AIS) on trace identifier mismatch.
- Suppress TIM: It will suppress TIM action.
|
Suppress TIM
|
- Ignore TIM
- Report TIM, No Downstream AIS
- Downstream AIS on TIM
- Suppress TIM
|
Signal Label Mismatch Action
|
Allows you to select the action for signal label mismatch.
- Ignore SLM: No action on Signal Label Mismatch (SLM).
- Report SLM, No Downstream AIS: On Signal Label Mismatch (SLM), HP_PLM alarm is reported but no downstream Alarm Indication Signal (AIS) is sent.
- Downstream AIS on SLM: Report HP_PLM alarm and send, Alarm Indication Signal (AIS) downstream (traffic affecting), on Signal Label Mismatch(SLM).
- Suppress SLM: It will suppress SLM action.
|
Report SLM, No Downstream AIS
|
- Ignore SLM
- Report SLM, No Downstream AIS
- Downstream AIS on SLM
- Suppress SLM
|
UNEQ Signal Label Action
|
Allows you to select the action for UNEQ signal label.
- Ignore UNEQ: It ignores UNEQ alarm.
- Report UNEQ, No Downstream AIS: It reports UNEQ alarm, does not send downstream AIS.
- Downstream AIS on UNEQ: It sends downstream alarm indication signal (AIS) on UNEQ signal label mismatch.
- Suppress UNEQ: It will suppress UNEQ signal label action.
|
Report UNEQ, No Downstream AIS
|
- Ignore UNEQ
- Report UNEQ, No Downstream AIS
- Downstream AIS on UNEQ
- Suppress UNEQ
|
Masked Alarms List or Select Alarms for Masking
|
List of masked alarms. The alarms that can be masked are:
- Alarm Indication Signal
- Remote Defect Indication
- Loss Of Pointer
- Signal Degrade
- Signal Fail
- E4
|
--
|
--
|