This cross-connect card performs processing, data path processing, cross-connect switching, fabric and timing functions. HCPXCC03 card supports bandwidth of 340G Higher Order cross-connects in the system. HCPXCC03 card is supported in slot 5 and slot 6 of the TJ1600 Type-11SR chassis.
STATIC DISCHARGE WARNING: Static charge can damage the equipment. While handling cards for making system interconnections, wear an ESD strap to discharge the static buildup.
The front panel has a two LEDs, Status and Active along with an early ejection switch. Apart from LEDs, the front panel has connectors for DIAG interface. OSC port is not supported in this product release.
The following figure shows the front panel view of HCPXCC03 card:
Specification |
Range |
---|---|
Input Voltage |
-48V DC |
Power consumption |
200W |
The visual indicators on the HCPXCC03 card include two LEDs, the Active and the Status LEDs.
Operation |
Master card Status LED and Active LED |
Slave card Status LED and Active LED |
||
---|---|---|---|---|
Power On: First LED activity noticed on card insertion. NOTE: The amber LED should be wired to be activated by default during hardware power-up or reset until software is up and running and can override it. |
Amber |
Amber |
Amber |
Amber |
Card OOS: Initialization complete and the card is in Out-Of-Service state (and not failed). |
Green |
Green |
Amber |
Off |
Card failed during boot-up. |
Red |
Amber |
Amber |
Amber |
Hard reset: All devices reset, fpga cleared and reprogrammed. Node goes to initializing state. |
Amber |
Amber |
Amber |
Amber |
Soft reset: Software is restarted and devices are re-initialized with provisioning. |
Amber |
Amber |
Amber |
Amber |
Early ejector is not jacked in properly. |
Amber blinking |
Off |
Amber blinking |
Off |
Wait for early ejector removal. |
Amber |
Off |
Amber |
Off |
Early ejector ready for jack-out. |
Amber blinking |
Off |
Amber blinking |
Off |
The Diag interface is a USB connector provided on the front panel of the HCPXCC03 card. This interface offers a serial connection to node using which a user can launch a terminal session to log onto the Operating System.
NOTE: The diagnostic interface is meant for use by authorized Tejas Networks personnel only.
HCPXCC03 card supports the following functional features:
The key functions of HCPXCC03 card are as follows:
The software residing in this block controls the overall management of the system. This function is also responsible for implementing watchdog logic for the system.
Synchronization Status Messaging (SSM) is implemented in the software to propagate the clock quality information to neighboring elements and to select the best quality clock among a set of nominated clock sources. The synchronization unit is commonly called the timing module.