This topic details the slot distribution of the cards supported in TJ1600 Type-11SR, TJ1600 Type-6SR and TJ1600 Type-2SR systems.
NOTE: Only TJ1600 Type-6SR and TJ1600 Type-2SR chassis can be configured both in 200G mode and 400G mode.
Lower order client types are not supported in 400G mode.
In this release, SONET mode is also supported for TJ1600 Type-11SR, TJ1600 Type-6SR and TJ1600 Type-2SR chassis in addition to SDH mode. However, the following conditions apply:
SDH |
SONET |
STM-1 |
OC-3 |
STM-4 |
OC-12 |
STM-16 |
OC-48 |
STM-64 |
OC-192 |
NOTE: High power OFA (OFA-C-S26-FG/OFA-C-S23-FG), MDU-40E-C-100G and MDU-40O-C-100G, PSCM, MDU-96-C-50G, ORA-C-450-FG are standalone units and not installed on the chassis. Therefore, no slot numbers are assigned to these cards.
Cards
|
Configuration
|
No. Service Ports
|
Slot number
|
Support
|
|||
XCC03 |
XCC04 |
OSMC |
|||||
HCPPFU02 |
-- |
Used in TJ1600 Type-11SR chassis to supply power. |
12 and 13 |
Yes |
Yes |
Yes |
|
HCPFTU01 |
-- |
Used in TJ1600 Type-11SR chassis to cool the equipment. |
15 |
Yes |
Yes |
Yes |
|
HCPOAM01 |
-- |
Provides static user interfaces for managing OAM of TJ1600 Type-11SR system. |
14 |
Yes |
Yes |
Yes |
|
|
|||||||
|
|||||||
|
|||||||
HCPSLine01 |
-- |
2xSTM-64/10GE |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
No |
|
HCPULine01 |
-- |
20xSTM-1/4 or 8xSTM-16 or 16x1GE ports (Except P5, P10, P15, P20) |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
No |
|
HCPSLine03
|
SDH Gateway Card NOTE: Fresh card configuration not supported for XCC04. |
4xSTM-64/10GE |
1, 2, 3, 4, 7, 8, 9, 10, 11
|
Yes
|
Yes |
No |
|
|
|||||||
|
|||||||
SDH FEC Card NOTE: Fresh card configuration not supported for XCC04. |
4xSTM-64 with FEC option |
Yes |
Yes |
No |
|||
OTN Flexi card |
4xSTM-64/10GE/OTU2/OTU2e |
No |
Yes |
No |
|||
IntraCard TRANS/MUXPONDER
|
4xSTM-64/10GE/OTU2/OTU2e
|
Yes |
Yes |
Yes |
|||
|
|||||||
HCPSLine08 |
SDH Gateway Card NOTE: Fresh card configuration not supported for XCC04. |
P1 and P2: 2xSTM-64/10GE + P3 to P10: 8xSTM-16 or P3 to P18: 16xSTM-1/4/1GE |
1, 2, 3, 4, 7, 8, 9, 10, 11
|
Yes
|
Yes |
No |
|
OTN Flexi card |
P1 and P2: 2xSTM-64/10GE/OTU2/OTU2e + P3 to P10: 8xSTM-16/OTU1 or P3 to P18: 16xSTM-1/4/1GE |
No |
Yes |
No |
|||
IntraCard TRANS/MUXPONDER |
P1 and P2: OTU2 + P3 to P10: STM-16/OTU1 or P3 to P18: 16xSTM-1/4/1GE |
Yes |
Yes |
Yes |
|||
HCPSLine12
|
10X10G TO 1XOTU4 MUXPONDER |
P1: OTU4 + P4 to P13: STM-64/10GE/OTU2/OTU2e/8GFC/12GFC |
1, 2, 3, 4, 7, 8, 9, 10, 11
|
Yes |
Yes |
Yes |
|
Flexi 100G plus 10x10G to OTU4 Muxponder |
P1: OTU4 P2:100GE P4 - P13: STM64/10GE LAN/OTU2/OTU2e/8GFC/12GFC |
Yes |
Yes |
Yes |
|||
Flexi 2x40G plus 10x10G to OTU4 Muxponder |
P1: OTU4, P2 and P3: 40GE P4 - P13: STM64/10GE LAN/OTU2/OTU2e/8GFC/12GFC |
Yes |
Yes |
Yes |
|||
HCPSLine20 |
SDH Only |
4xSTM-64/16/4/1 + 28xSTM-16/4/1 or 6xSTM-64/16/4/1 + 26xSTM-16/4/1 |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
No |
Yes |
No |
|
HCPSLine22 |
10x10G SDH Flexi |
10xSTM-64/10GE |
1, 2, 3, 4, 7, 8, 9, 10, 11
|
No |
Yes |
No |
|
10X10G OTN TRIBUTARY |
P1 to P10: 10xSTM-64/10GE LAN/OTU2/OTU2e/8GFC OTU2/OTU2e ports (P1, P2, P7 and P9) support ODUj channelization. 10GE port support GFP mapping and ODUflex (P3 and P10) |
No |
Yes |
No |
|||
1x100G OTN TRIBUTARY |
P11: OTU4 |
No |
Yes |
No |
|||
5x10G TRANSPONDER |
P1 to P5: OTU2/OTU2e P6 to P10: STM-64/10GE/OTU2/OTU2e/OTU1f/8GFC/12GFC |
Yes |
Yes |
Yes |
|||
10x10G TO 1XOTU4 MUXPONDER |
P1 to P10: STM-64/10GE/OTU2/OTU2e + P11: OTU4 |
Yes |
Yes |
Yes |
|||
HCPSLine24 |
1X100G TRANSPONDER OTU4 NP |
P1: OTU4 + P4 : OTU4/100GE |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
|
HCPSLine25 |
10X10G TRANSPONDER |
P1 to P10: OTU2/OTU2e P11 to P20: STM-64/10GE/OTU2/OTU2e |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
|
HCPSLine26 |
20x10G to 2 OTU4 Muxponder |
P1: 100G (OTUC1)/200G (OTUC2) P2 - P21: STM64/10GE/OTU2/OTU2e/8GFC/12GFC |
1, 2, 3, 7, 8, 9, 10 NOTE: HCPSLine26 is not supported on slot 4 and slot 11. |
Yes |
Yes |
Yes |
|
HCPSLine27
|
10X10G to OTU4 Muxponder + Flexi 100G to OTU4 Transponder |
P1: 100G (OTUC1)/200G (OTUC2), P2: 100GE/OTU4 P4 - P13: STM64/10GE/OTU2/OTU2e/8GFC/12GFC |
1, 2, 3, 4, 7, 8, 9, 10, 11 NOTE: HCPSLine27 is not supported on slot 4 and slot 11. |
Yes |
Yes |
Yes |
|
Two Flexi 100G to 2 OTU4 Transponder |
P1: 100G (OTUC1)/200G (OTUC2), P2 and P3: 100GE/OTU4 |
Yes |
Yes |
Yes |
|||
HCPSLine28
|
1X100G TRANSPONDER OTU4 NP |
P1: OTU4 + P4 : OTU4/100GE |
1, 2, 3, 4, 7, 8, 9, 10, 11
|
Yes |
Yes |
Yes |
|
2x100G TRANSPONDER |
P1 and P4: OTU4 + P2 and P3: OTU4/100GE |
Yes |
Yes |
Yes |
|||
CEF-5
|
2*10G + 12*1G (default mode) |
2x10GE + 12x1GE + 32VCG |
1, 2, 3, 4, 7, 8, 9, 10, 11 One mesh switch in either 2, 3, 4 or 8, 9, 10
|
Yes |
Yes |
Yes |
|
6*10G + 12*G (License mode) |
6x10GE + 12X1GE + 32VCG |
Yes |
Yes |
Yes |
|||
8*10G (License mode) |
8X10GE + 16VCG |
Yes |
Yes |
Yes |
|||
OFA-C-S20-VG OFA-C-S20-LG OFA-C-S20-HG OFA-C-D20-VG OFA-C-D20-LG OFA-C-D20-HG |
-- |
Amplifier ports and Monitor ports. |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
|
OFA-C-S17-FG OFA-C-D17-FG |
-- |
Fixed Gain EDFA Single or Dual module design gives flat gain for all DWDM channels at the designed gain known as Designed Flat Gain (DFG). 17dBM gain modules. |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
|
OFA-C-S20-LVG OFA-C-D20-LVG OFA-C-D20-MVG |
-- |
S20-LVG: 20dBm single Ports Low Variable Gain DWDM amplifier D20-LVG: 20dBm dual port Low Variable Gain DWDM amplifier D20-MVG: 20dBm dual port Mixed Variable Gain (Low Gain +High Gain) DWDM amplifier. |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
|
ORA-C-450-FG |
- |
Enables longer reach spans for high loss networks. |
- |
Yes |
Yes |
Yes |
|
ROADM-2-C-50G/ROADM-4-C-50G |
-- |
Dynamically add drop any wavelength up to 80 Channels. |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
|
ROADM-8-C-50G |
-- |
Dynamically add drop any wavelength up to 80 Channels. |
2, 3, 4, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
|
MDU-16CL-C-50G |
-- |
16-channel multiplexer and demultiplexer active optical card. |
2, 3, 4, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
|
OPM-C-2 and OPM-C-4 |
-- |
OPM-C-4 is a 4 port and OPM-C-2 is a two port card which measure optical power from either 4 or 2 monitoring input ports. |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
|
HCPADP01 |
-- |
Accommodate both active cards and passive cards by dividing the slot into 2/3rd and 1/3rd slots; where 1/3rd supports FPU01, 2/3rd slot supports MDU-8-D card. |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
|
HCPADP02 |
-- |
Accommodate both active cards and passive cards by dividing a slot into two half slots; where 1/2nd slot supports VOA, OADM1 and OADM4 cards. |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
|
VOA |
-- |
Supports eight ports in which eight hot pluggable VOA SFP modules can be inserted. |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
|
OFA-C-S26-FG/OFA-C-S23-FG |
-- |
Provides a high output power of up to 26/23dBm. |
-- |
Yes |
Yes |
Yes |
|
FPU01 |
-- |
Provides protection against the optical fiber line failures. |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
|
MDU-40E-C-100G and MDU-40O-C-100G |
-- |
100GHz channel with even spacing (192.00 to 195.90 THz) and with odd spacing (192.05 to 195.95 THz). |
-- |
Yes |
Yes |
Yes |
|
MDU-8-D |
-- |
Add and drop 8 DWDM channels with 100GHz spacing. |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
|
MDU-16-D |
-- |
Adds and drop 16 DWDM channels with 100GHz spacing |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
|
MDU-96-C-50G |
-- |
The MDU-96-C-50G 50GHz channel spaced DWDM multiplexer and demultiplexer with two 50 GHz Athermal Arrayed Waveguide Grating (AAWG) optical mux/demux modules, one for multiplexing and one for demultiplexing. |
-- |
Yes |
Yes |
Yes |
|
PSCM |
-- |
Splits the signal into N (N>1) parts in one direction and combines the N signals to produce one signal in other direction. |
-- |
Yes |
Yes |
Yes |
|
OADM1 and OADM4 |
-- |
Adds and drops 1 and 4 channels at 100GHz spacing respectively. |
1, 2, 3, 4, 7, 8, 9, 10, 11 |
Yes |
Yes |
Yes |
NOTE: CEF-5 cards inserted in slots 1 will come up in standalone mode. If a mesh already exists in the system, then cards inserted in the other mesh slots will come up in standalone mode only.
In CEF-5 card, VCGs are supported in TJ1600 Type-11SR chassis when the Data Path Mode is selected as 'SDH'. VCGs are not supported on TJ1600 Type-11SR chassis with Data Path Mode as “OTN”.
ROADM-8-C-50G and MDU-16-CL-50G is a double slot card; hence cannot be used in slot 1 and slot 7 of the chassis.
Card |
Configuration |
No. of Service Ports |
Slot number |
---|---|---|---|
HCPSLine03 |
IntraCard TRANS/MUXPONDER |
|
1, 2, 3, 4 |
HCPSLine08 |
IntraCard TRANS/MUXPONDER |
P1 and P2: OTU2 muxponder + P3 to P10: STM16/OTU1 or P3 to P18: STM1/ STM4/ GE |
1, 2, 3, 4 |
HCPSLine12
|
10x10G TO 1xOTU4 MUXPONDER |
1xOTU4 + 10xSTM64/OTU2/OTU2e/10GE/8GFC/12GFC |
1, 2, 3, 4 |
Flexi 100G plus 10x10G to OTU4 Muxponder |
P1: OTU4,P2:100GE P4-P13: STM64/10GE LAN/OTU2/OTU2e/8GFC/12GFC |
||
Flexi 2x40G plus 10x10G to OTU4 Muxponder |
P1: OTU4, P2 & P3: 40GE P4-P13: STM64/10GE LAN/OTU2/OTU2e/8GFC/12GFC |
||
HCPSLine22
|
10x10G FLEXI TRIBUTARY AND CROSS-CONNECT (gFEC and eFEC) NOTE: If node is configured in 200G mode, only slot1 & 2 supports cross connect mode. |
|
1, 2, 3, 4
|
10x10G TO 1xOTU4 MUXPONDER |
P1 to P10: STM64/10GE/OTU2/OTU2e/8GFC + P11: OTU4 |
||
5x10G TRANSPONDER (gFEC and eFEC) |
|
||
10x10G 1x100G TRIBUTARY AND CROSS-CONNECT NOTE: If node is configured in 400G mode, only slot1 & 2 supports cross connect mode. |
|
||
HCPSLine24 |
1x100G Transponder OTU4 NP |
1xOTU4/100GE (P4) + 1xOTU4 (P1) |
1, 2, 3, 4 |
HCPSLine25 |
10x10G Transponder |
|
1, 2, 3, 4 |
HCPSLine26 |
20x10G to 2 OTU4 Muxponder |
P1:100G (OTUC1)/200G (OTUC2) P2 - P21: STM64/10GE/OTU2/OTU2e/8GFC/12GFC |
1, 2, 3, 4, |
HCPSLine27
|
10X10G to OTU4 Muxponder + Flexi 100G to OTU4 Transponder |
P1: 100G (OTUC1)/200G (OTUC2), P2: 100GE/OTU4 P4-P13: STM64/10GE/OTU2/OTU2e/8GFC/12GFC |
1, 2, 3, 4
|
Two Flexi 100G to 2 OTU4 Transponder |
P1: 100G (OTUC1)/200G (OTUC2), P2 & P3: 100GE/OTU4 |
||
HCPSLine28
|
1x100G Transponder OTU4 NP |
1xOTU4 (P1) + 1xOTU4/100GE (P4) |
1, 2, 3, 4 |
2x100G Transponder OTU4 NP |
2xOTU4 (P1 and P4) + 2xOTU4/100GE (P2 and P3) |
||
CEF-5 |
2*10G + 12*1G (default mode) |
2x10GE + 12x1GE + 32VCG |
1, 2, 3, 4 One mesh switch in either 2, 3, 4 NOTE 1: Cards inserted in slots 1 will come up in standalone mode. If a mesh already exists in the system, then cards inserted in the other mesh slots will come up in standalone mode only. NOTE 2: VCG is not supported in this release. |
|
6*10G + 12*1G (License mode) |
6x10GE + 12x1GE + 32VCG |
|
8*10G (License mode) |
8x10GE + 16VCG |
||
OFA-C-S20-VG OFA-C-S20-LG OFA-C-S20-HG OFA-C-D20-VG OFA-C-D20-LG OFA-C-D20-HG |
-- |
Amplifier ports and Monitor ports. |
1, 2, 3, 4 |
OFA-C-S17-FG OFA-C-D17-FG |
-- |
Fixed Gain EDFA Single or Dual module design gives flat gain for all DWDM channels at the designed gain known as Designed Flat Gain (DFG). 17dBM gain modules. |
1, 2, 3, 4 |
OFA-C-S20-LVG OFA-C-D20-LVG OFA-C-D20-MVG |
-- |
S20-LVG: 20dBm single Ports Low Variable Gain DWDM amplifier D20-LVG: 20dBm double port Low Variable Gain DWDM amplifier D20-MVG: 20dBm dual port Mixed Variable Gain (Low Gain +High Gain) DWDM amplifier |
1, 2, 3, 4 |
MDU-8-D |
-- |
Add and drop 8 DWDM channels with 100GHz spacing. |
1, 2, 3, 4 |
MDU-40E-C-100G and MDU-40O-C-100G |
-- |
100GHz channel with even spacing (192.00 to 195.90 THz) and with odd spacing (192.05 to 195.95 THz). It is a passive optical unit. |
-- |
MDU-96-C-50G |
-- |
The MDU-96-C-50G 50GHz channel spaced DWDM multiplexer and demultiplexer with two 50 GHz Athermal Arrayed Waveguide Grating (AAWG) optical mux/demux modules, one for multiplexing and one for demultiplexing. |
-- |
ORA-C-450-FG |
-- |
Enables longer reach spans for high loss networks. |
-- |
ROADM-2-C-50G/ROADM-4-C-50G |
-- |
Dynamically add drop any wavelength up to 80 Channels. |
1, 2, 3, 4 |
ROADM-8-C-50G |
-- |
Dynamically add drop any wavelength up to 80 Channels. |
2, 3, 4 NOTE: ROADM-8-C-50G is a double slot card, hence this card cannot be installed on slot 1 of the chassis. |
OPM-C-4 and OPM-C-2 |
-- |
OPM-C-4 is a 4 port and OPM-C-2 is a two port card which measure optical power from either 4 or 2 monitoring input ports. |
1, 2, 3, 4 |
FPU01 |
-- |
Provides protection against the optical fiber line failures. |
1, 2, 3, 4 |
HCPADP01 |
-- |
Accommodate both active cards and passive cards by dividing the slot into 2/3rd and 1/3rd slots; where 1/3rd supports FPU01, 2/3rd slot supports MDU-8-D card. |
1, 2, 3, 4 |
HCPADP02 |
-- |
Accommodate both active cards and passive cards by dividing a slot into two half slots; where 1/2nd slot supports VOA, OADM1 and OADM4 cards. |
1, 2, 3, 4 |
FPUADP01 |
-- |
Accommodates the FPU01 in the 2/3rd slot of HCPADP01. |
1, 2, 3, 4 |
VOA |
-- |
Supports eight ports in which eight hot pluggable VOA SFP modules can be inserted. |
1, 2, 3, 4 |
PSCM |
-- |
Splits the signal into N (N>1) parts in one direction and combines the N signals to produce one signal in other direction. |
-- |
OFA-C-S26-FG/OFA-C-S23-FG |
-- |
Provides a high output power of up to 26/23dBm. |
-- |
OADM1 and OADM4 |
-- |
Adds and drops 1 and 4 channels at 100GHz spacing respectively. |
1, 2, 3, 4 |
MDU-16-D |
-- |
Adds and drop 16 DWDM channels with 100GHz spacing |
1, 2, 3, 4 |
MDU-16CL-C-50G |
-- |
16-channel multiplexer and demultiplexer active optical card. |
2, 3, 4 NOTE: MDU-16CL-C-50G is a double slot card, hence this card cannot be installed on slot 1 of the chassis. |
Card |
Configuration |
No. of Service Ports |
Slot number |
---|---|---|---|
HCPSLine03 |
IntraCard TRANS/MUXPONDER |
|
1, 2 |
HCPSLine08 |
IntraCard TRANS/MUXPONDER |
2xOTU2 + 8xSTM16/OTU1 or 16x GE/STM1/STM4 |
1, 2 |
HCPSLine12
|
10x10G TO 1xOTU4 MUXPONDER |
1xOTU4 + 10xSTM64/OTU2/OTU2e/10GE/8GFC/12GFC |
1, 2
|
Flexi 100G plus 10x10G to OTU4 Muxponder |
P1: OTU4,P2:100GE P4-P13: STM64/10GE LAN/OTU2/OTU2e/8GFC/12GFC |
||
Flexi 2x40G plus 10x10G to OTU4 Muxponder |
P1: OTU4, P2 & P3: 40GE P4-P13: STM64/10GE LAN/OTU2/OTU2e/8GFC/12GFC |
||
HCPSLine22
|
10x10G 1x100G TRIBUTARY AND CROSS-CONNECT |
P1 to P10: STM64/10GE LAN/OTU2/OTU2e/8GFC P11: OTU4 |
1, 2 |
10x10G FLEXI TRIBUTARY AND CROSS-CONNECT (gFEC and eFEC) |
|
||
HCPSLine24 |
1x100G Transponder OTU4 NP |
1xOTU4/100GE (P4) + 1xOTU4 (P1) |
1, 2 |
HCPSLine25 |
10x10G Transponder |
|
1, 2 |
HCPSLine26 |
20x10G to 2 OTU4 Muxponder |
P1: OTUC1/OTUC2 P2 - P21: STM64/10GE/OTU2/OTU2e/8GFC/12GFC |
1, 2, |
HCPSLine27
|
10X10G to OTU4 Muxponder + Flexi 100G to OTU4 Transponder |
P1: OTUC1/OTUC2, P2: 100GE/OTU4 P4-P13: STM64/10GE/OTU2/OTU2e/8GFC/12GFC |
1, 2
|
Two Flexi 100G to 2 OTU4 Transponder |
P1: OTUC1/OTUC2, P2 & P3: 100GE/OTU4 |
||
HCPSLine28
|
1x100G Transponder OTU4 NP |
1xOTU4 (P1) + 1xOTU4/100GE (P4) |
1, 2 |
2X100G Transponder 100GE NP (100GE) |
2xOTU4 (P1 and P4) + 2xOTU4/100GE (P2 and P3) |
||
OFA-C-S20-VG OFA-C-S20-LG OFA-C-S20-HG OFA-C-D20-VG OFA-C-D20-LG OFA-C-D20-HG |
-- |
Amplifier ports and Monitor ports. |
1, 2 |
OFA-C-S17-FG OFA-C-D17-FG |
-- |
Fixed Gain EDFA Single or Dual module design gives flat gain for all DWDM channels at the designed gain known as Designed Flat Gain (DFG). 17dBM gain modules. |
1, 2 |
OFA-C-S20-LVG OFA-C-D20-LVG OFA-C-D20-MVG |
-- |
S20-LVG: 20dBm single Ports Low Variable Gain DWDM amplifier D20-LVG: 20dBm double port Low Variable Gain DWDM amplifier D20-MVG: 20dBm dual port Mixed Variable Gain (Low Gain +High Gain) DWDM amplifier |
1, 2 |
OFA-C-S26-FG/OFA-C-S23-FG |
-- |
Provides a high output power of up to 26/23dBm. |
-- |
ORA-C-450-FG |
-- |
Enables longer reach spans for high loss networks. |
-- |
HCPADP01 |
-- |
Accommodate both active and passive cards by dividing the slot into 2/3rd and 1/3rd slots. |
1, 2 |
HCPADP02 |
-- |
Accommodate both active cards and passive cards by dividing a slot into two half slots; where 1/2nd slot supports VOA, OADM1 and OADM4 cards. |
1, 2 |
MDU-8-D |
-- |
Add and drop 8 DWDM channels with 100GHz spacing. |
1, 2 |
MDU-16-D |
-- |
Adds and drop 16 DWDM channels with 100GHz spacing |
1, 2 |
MDU-96-C-50G |
-- |
The MDU-96-C-50G 50GHz channel spaced DWDM multiplexer and demultiplexer with two 50 GHz Athermal Arrayed Waveguide Grating (AAWG) optical mux/demux modules, one for multiplexing and one for demultiplexing. |
-- |
OADM1 and OADM4 |
-- |
Adds and drops 1 and 4 channels at 100GHz spacing respectively. |
1, 2 |
OPM-C-4 and OPM-C-2 |
-- |
OPM-C-4 is a 4 port and OPM-C-2 is a two port card which measure optical power from either 4 or 2 monitoring input ports. |
1, 2 |
VOA |
-- |
Supports eight ports in which eight hot pluggable VOA SFP modules can be inserted. |
1, 2 |
PSCM |
-- |
Splits the signal into N (N>1) parts in one direction and combines the N signals to produce one signal in other direction. |
-- |
MDU-40E-C-100G and MDU-40O-C-100G |
-- |
100GHz channel with even spacing (192.00 to 195.90 THz) and with odd spacing (192.05 to 195.95 THz). It is a passive optical unit. |
-- |
FPU01 |
-- |
Provides protection against the optical fiber line failures. |
Pluggable in the HCPADP01 card that occupies 1/3rd slot. |