Slot Distribution

This topic details the slot distribution of the cards supported in TJ1600 Type-11SR, TJ1600 Type-6SR and TJ1600 Type-2SR systems.

NOTE: Only TJ1600 Type-6SR and TJ1600 Type-2SR chassis can be configured both in 200G mode and 400G mode.

Lower order client types are not supported in 400G mode.

In this release, SONET mode is also supported for TJ1600 Type-11SR, TJ1600 Type-6SR and TJ1600 Type-2SR chassis in addition to SDH mode. However, the following conditions apply:

SDH

SONET

STM-1

OC-3

STM-4

OC-12

STM-16

OC-48

STM-64

OC-192

NOTE: High power OFA (OFA-C-S26-FG/OFA-C-S23-FG), MDU-40E-C-100G and MDU-40O-C-100G, PSCM, MDU-96-C-50G, ORA-C-450-FG are standalone units and not installed on the chassis. Therefore, no slot numbers are assigned to these cards.

Slot distribution of TJ1600 Type-11SR

Cards

 

Configuration

 

No. Service Ports

 

Slot number

 

Support

 

XCC03

XCC04

OSMC

HCPPFU02

--

Used in TJ1600 Type-11SR chassis to supply power.

12 and 13

Yes

Yes

Yes

HCPFTU01

--

Used in TJ1600 Type-11SR chassis to cool the equipment.

15

Yes

Yes

Yes

HCPOAM01

--

Provides static user interfaces for managing OAM of TJ1600 Type-11SR system.

14

Yes

Yes

Yes

 

 

 

HCPSLine01

--

2xSTM-64/10GE

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

No

HCPULine01

--

20xSTM-1/4 or 8xSTM-16 or 16x1GE ports (Except P5, P10, P15, P20)

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

No

HCPSLine03

 

SDH Gateway Card

NOTE: Fresh card configuration not supported for XCC04.

4xSTM-64/10GE

1, 2, 3, 4, 7, 8, 9, 10, 11

 

Yes

 

Yes

No

 

 

SDH FEC Card

NOTE: Fresh card configuration not supported for XCC04.

4xSTM-64 with FEC option

Yes

Yes

No

OTN Flexi card

4xSTM-64/10GE/OTU2/OTU2e

No

Yes

No

IntraCard TRANS/MUXPONDER

 

4xSTM-64/10GE/OTU2/OTU2e

 

Yes

Yes

Yes

 

HCPSLine08

SDH Gateway Card

NOTE: Fresh card configuration not supported for XCC04.

P1 and P2: 2xSTM-64/10GE + P3 to P10: 8xSTM-16 or P3 to P18: 16xSTM-1/4/1GE

1, 2, 3, 4, 7, 8, 9, 10, 11

 

Yes

 

Yes

No

OTN Flexi card

P1 and P2: 2xSTM-64/10GE/OTU2/OTU2e + P3 to P10: 8xSTM-16/OTU1 or P3 to P18: 16xSTM-1/4/1GE

No

Yes

No

IntraCard TRANS/MUXPONDER

P1 and P2: OTU2 + P3 to P10: STM-16/OTU1 or P3 to P18: 16xSTM-1/4/1GE

Yes

Yes

Yes

HCPSLine12

 

10X10G TO 1XOTU4 MUXPONDER

P1: OTU4 + P4 to P13: STM-64/10GE/OTU2/OTU2e/8GFC/12GFC

1, 2, 3, 4, 7, 8, 9, 10, 11

 

Yes

Yes

Yes

Flexi 100G plus 10x10G to OTU4 Muxponder

P1: OTU4

P2:100GE

P4 - P13: STM64/10GE LAN/OTU2/OTU2e/8GFC/12GFC

Yes

Yes

Yes

Flexi 2x40G plus 10x10G to OTU4 Muxponder

P1: OTU4,

P2 and P3: 40GE

P4 - P13: STM64/10GE LAN/OTU2/OTU2e/8GFC/12GFC

Yes

Yes

Yes

HCPSLine20

SDH Only

4xSTM-64/16/4/1 + 28xSTM-16/4/1 or 6xSTM-64/16/4/1 + 26xSTM-16/4/1

1, 2, 3, 4, 7, 8, 9, 10, 11

No

Yes

No

HCPSLine22

10x10G SDH Flexi

10xSTM-64/10GE

1, 2, 3, 4, 7, 8, 9, 10, 11

 

No

Yes

No

10X10G OTN TRIBUTARY

P1 to P10: 10xSTM-64/10GE LAN/OTU2/OTU2e/8GFC

OTU2/OTU2e ports (P1, P2, P7 and P9) support ODUj channelization.

10GE port support GFP mapping and ODUflex (P3 and P10)

No

Yes

No

1x100G OTN TRIBUTARY

P11: OTU4

No

Yes

No

5x10G TRANSPONDER

P1 to P5: OTU2/OTU2e

P6 to P10: STM-64/10GE/OTU2/OTU2e/OTU1f/8GFC/12GFC

Yes

Yes

Yes

10x10G TO 1XOTU4 MUXPONDER

P1 to P10: STM-64/10GE/OTU2/OTU2e + P11:

OTU4

Yes

Yes

Yes

HCPSLine24

1X100G TRANSPONDER OTU4 NP

P1: OTU4 + P4 : OTU4/100GE

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

HCPSLine25

10X10G TRANSPONDER

P1 to P10: OTU2/OTU2e

P11 to P20: STM-64/10GE/OTU2/OTU2e

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

HCPSLine26

20x10G to 2 OTU4 Muxponder

P1: 100G (OTUC1)/200G (OTUC2)

P2 - P21: STM64/10GE/OTU2/OTU2e/8GFC/12GFC

1, 2, 3, 7, 8, 9, 10

NOTE: HCPSLine26 is not supported on slot 4 and slot 11.

Yes

Yes

Yes

HCPSLine27

 

10X10G to OTU4 Muxponder + Flexi 100G to OTU4 Transponder

P1: 100G (OTUC1)/200G (OTUC2), P2: 100GE/OTU4

P4 - P13: STM64/10GE/OTU2/OTU2e/8GFC/12GFC

1, 2, 3, 4, 7, 8, 9, 10, 11

NOTE: HCPSLine27 is not supported on slot 4 and slot 11.

Yes

Yes

Yes

Two Flexi 100G to 2 OTU4 Transponder

P1: 100G (OTUC1)/200G (OTUC2),

P2 and P3: 100GE/OTU4

Yes

Yes

Yes

HCPSLine28

 

1X100G TRANSPONDER OTU4 NP

P1: OTU4 + P4 : OTU4/100GE

1, 2, 3, 4, 7, 8, 9, 10, 11

 

Yes

Yes

Yes

2x100G TRANSPONDER

P1 and P4: OTU4 + P2 and P3: OTU4/100GE

Yes

Yes

Yes

CEF-5

 

2*10G + 12*1G (default mode)

2x10GE + 12x1GE + 32VCG

1, 2, 3, 4, 7, 8, 9, 10, 11 One mesh switch in either 2, 3, 4 or 8, 9, 10

 

Yes

Yes

Yes

6*10G + 12*G (License mode)

6x10GE + 12X1GE + 32VCG

Yes

Yes

Yes

8*10G (License mode)

8X10GE + 16VCG

Yes

Yes

Yes

OFA-C-S20-VG

OFA-C-S20-LG

OFA-C-S20-HG

OFA-C-D20-VG

OFA-C-D20-LG

OFA-C-D20-HG

--

Amplifier ports and Monitor ports.

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

OFA-C-S17-FG

OFA-C-D17-FG

--

Fixed Gain EDFA Single or Dual module design gives flat gain for all DWDM channels at the designed gain known as Designed Flat Gain (DFG). 17dBM gain modules.

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

OFA-C-S20-LVG

OFA-C-D20-LVG

OFA-C-D20-MVG

--

S20-LVG: 20dBm single Ports Low Variable Gain DWDM amplifier

D20-LVG: 20dBm dual port Low Variable Gain DWDM amplifier

D20-MVG: 20dBm dual port Mixed Variable Gain (Low Gain +High Gain) DWDM amplifier.

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

ORA-C-450-FG

-

Enables longer reach spans for high loss networks.

-

Yes

Yes

Yes

ROADM-2-C-50G/ROADM-4-C-50G

--

Dynamically add drop any wavelength up to 80 Channels.

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

ROADM-8-C-50G

--

Dynamically add drop any wavelength up to 80 Channels.

2, 3, 4, 8, 9, 10, 11

Yes

Yes

Yes

MDU-16CL-C-50G

--

16-channel multiplexer and demultiplexer active optical card.

2, 3, 4, 8, 9, 10, 11

Yes

Yes

Yes

OPM-C-2 and OPM-C-4

--

OPM-C-4 is a 4 port and OPM-C-2 is a two port card which measure optical power from either 4 or 2 monitoring input ports.

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

HCPADP01

--

Accommodate both active cards and passive cards by dividing the slot into 2/3rd and 1/3rd slots; where 1/3rd supports FPU01, 2/3rd slot supports MDU-8-D card.

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

HCPADP02

--

Accommodate both active cards and passive cards by dividing a slot into two half slots; where 1/2nd slot supports VOA, OADM1 and OADM4 cards.

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

VOA

--

Supports eight ports in which eight hot pluggable VOA SFP modules can be inserted.

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

OFA-C-S26-FG/OFA-C-S23-FG

--

Provides a high output power of up to 26/23dBm.

--

Yes

Yes

Yes

FPU01

--

Provides protection against the optical fiber line failures.

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

MDU-40E-C-100G and MDU-40O-C-100G

--

100GHz channel with even spacing (192.00 to 195.90 THz) and with odd spacing (192.05 to 195.95 THz).

--

Yes

Yes

Yes

MDU-8-D

--

Add and drop 8 DWDM channels with 100GHz spacing.

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

MDU-16-D

--

Adds and drop 16 DWDM channels with 100GHz spacing

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

MDU-96-C-50G

--

The MDU-96-C-50G 50GHz channel spaced DWDM multiplexer and demultiplexer with two 50 GHz Athermal Arrayed Waveguide Grating (AAWG) optical mux/demux modules, one for multiplexing and one for demultiplexing.

--

Yes

Yes

Yes

PSCM

--

Splits the signal into N (N>1) parts in one direction and combines the N signals to produce one signal in other direction.

--

Yes

Yes

Yes

OADM1 and OADM4

--

Adds and drops 1 and 4 channels at 100GHz spacing respectively.

1, 2, 3, 4, 7, 8, 9, 10, 11

Yes

Yes

Yes

NOTE: CEF-5 cards inserted in slots 1 will come up in standalone mode. If a mesh already exists in the system, then cards inserted in the other mesh slots will come up in standalone mode only.

In CEF-5 card, VCGs are supported in TJ1600 Type-11SR chassis when the Data Path Mode is selected as 'SDH'. VCGs are not supported on TJ1600 Type-11SR chassis with Data Path Mode as “OTN”.

ROADM-8-C-50G and MDU-16-CL-50G is a double slot card; hence cannot be used in slot 1 and slot 7 of the chassis.

Slot distribution of TJ1600 Type-6SR

Slot distribution for TJ1600 Type-6SR

Card

Configuration

No. of Service Ports

Slot number

HCPSLine03

IntraCard TRANS/MUXPONDER

  • P1 to P4: 4 x STM64
  • Supports 10GE ports

1, 2, 3, 4

HCPSLine08

IntraCard TRANS/MUXPONDER

P1 and P2: OTU2 muxponder + P3 to P10: STM16/OTU1 or P3 to P18: STM1/ STM4/ GE

1, 2, 3, 4

HCPSLine12

 

10x10G TO 1xOTU4 MUXPONDER

1xOTU4 + 10xSTM64/OTU2/OTU2e/10GE/8GFC/12GFC

1, 2, 3, 4

Flexi 100G plus 10x10G to OTU4 Muxponder

P1: OTU4,P2:100GE

P4-P13: STM64/10GE LAN/OTU2/OTU2e/8GFC/12GFC

Flexi 2x40G plus 10x10G to OTU4 Muxponder

P1: OTU4, P2 & P3: 40GE

P4-P13: STM64/10GE LAN/OTU2/OTU2e/8GFC/12GFC

HCPSLine22

 

10x10G FLEXI TRIBUTARY AND CROSS-CONNECT (gFEC and eFEC)

NOTE: If node is configured in 200G mode, only slot1 & 2 supports cross connect mode.

  • P3, P4, P5, P6, P8 and P10 STM1/4/16/64/10GE/1GE/1GFC/2GFC/8GFC
  • P1, P2, P7 and P9: OTU2/OTU2e/OTU1e/STM1/4/16/64/10GE/1GE/1GFC/2GFC/8GFC

1, 2, 3, 4

 

10x10G TO 1xOTU4 MUXPONDER

P1 to P10: STM64/10GE/OTU2/OTU2e/8GFC + P11: OTU4

5x10G TRANSPONDER (gFEC and eFEC)

  • P1 to P5: OTU2/OTU2e/OTU1f
  • P6 to P10: STM64/10GE/OTU2/OTU2e/8GFC/12GFC

10x10G 1x100G TRIBUTARY AND CROSS-CONNECT

NOTE: If node is configured in 400G mode, only slot1 & 2 supports cross connect mode.

  • Ports P1 to P10: STM64/10GELAN/OTU2/OTU2e/8GFC
  • P11: OTU4

HCPSLine24

1x100G Transponder OTU4 NP

1xOTU4/100GE (P4) + 1xOTU4 (P1)

1, 2, 3, 4

HCPSLine25

10x10G Transponder

  • Ports P1 to P10: OTU2/OTU2e
  • P11 to P20: STM-64/10GE/OTU2/OTU2e/8GFC/12GFC

1, 2, 3, 4

HCPSLine26

20x10G to 2 OTU4 Muxponder

P1:100G (OTUC1)/200G (OTUC2)

P2 - P21: STM64/10GE/OTU2/OTU2e/8GFC/12GFC

1, 2, 3, 4,

HCPSLine27

 

10X10G to OTU4 Muxponder + Flexi 100G to OTU4 Transponder

P1: 100G (OTUC1)/200G (OTUC2), P2: 100GE/OTU4

P4-P13: STM64/10GE/OTU2/OTU2e/8GFC/12GFC

1, 2, 3, 4

 

Two Flexi 100G to 2 OTU4 Transponder

P1: 100G (OTUC1)/200G (OTUC2), P2 & P3: 100GE/OTU4

HCPSLine28

 

1x100G Transponder OTU4 NP

1xOTU4 (P1) + 1xOTU4/100GE (P4)

1, 2, 3, 4

2x100G Transponder OTU4 NP

2xOTU4 (P1 and P4) + 2xOTU4/100GE (P2 and P3)

CEF-5

2*10G + 12*1G (default mode)

2x10GE + 12x1GE + 32VCG

1, 2, 3, 4

One mesh switch in either 2, 3, 4

NOTE 1: Cards inserted in slots 1 will come up in standalone mode. If a mesh already exists in the system, then cards inserted in the other mesh slots will come up in standalone mode only.

NOTE 2: VCG is not supported in this release.

 

6*10G + 12*1G (License mode)

6x10GE + 12x1GE + 32VCG

 

8*10G (License mode)

8x10GE + 16VCG

OFA-C-S20-VG

OFA-C-S20-LG

OFA-C-S20-HG

OFA-C-D20-VG

OFA-C-D20-LG

OFA-C-D20-HG

--

Amplifier ports and Monitor ports.

1, 2, 3, 4

OFA-C-S17-FG

OFA-C-D17-FG

--

Fixed Gain EDFA Single or Dual module design gives flat gain for all DWDM channels at the designed gain known as Designed Flat Gain (DFG). 17dBM gain modules.

1, 2, 3, 4

OFA-C-S20-LVG

OFA-C-D20-LVG

OFA-C-D20-MVG

--

S20-LVG: 20dBm single Ports Low Variable Gain DWDM amplifier

D20-LVG: 20dBm double port Low Variable Gain DWDM amplifier

D20-MVG: 20dBm dual port Mixed Variable Gain (Low Gain +High Gain) DWDM amplifier

1, 2, 3, 4

MDU-8-D

--

Add and drop 8 DWDM channels with 100GHz spacing.

1, 2, 3, 4

MDU-40E-C-100G and MDU-40O-C-100G

--

100GHz channel with even spacing (192.00 to 195.90 THz) and with odd spacing (192.05 to 195.95 THz). It is a passive optical unit.

--

MDU-96-C-50G

--

The MDU-96-C-50G 50GHz channel spaced DWDM multiplexer and demultiplexer with two 50 GHz Athermal Arrayed Waveguide Grating (AAWG) optical mux/demux modules, one for multiplexing and one for demultiplexing.

--

ORA-C-450-FG

--

Enables longer reach spans for high loss networks.

--

ROADM-2-C-50G/ROADM-4-C-50G

--

Dynamically add drop any wavelength up to 80 Channels.

1, 2, 3, 4

ROADM-8-C-50G

--

Dynamically add drop any wavelength up to 80 Channels.

2, 3, 4

NOTE: ROADM-8-C-50G is a double slot card, hence this card cannot be installed on slot 1 of the chassis.

OPM-C-4 and OPM-C-2

--

OPM-C-4 is a 4 port and OPM-C-2 is a two port card which measure optical power from either 4 or 2 monitoring input ports.

1, 2, 3, 4

FPU01

--

Provides protection against the optical fiber line failures.

1, 2, 3, 4

HCPADP01

--

Accommodate both active cards and passive cards by dividing the slot into 2/3rd and 1/3rd slots; where 1/3rd supports FPU01, 2/3rd slot supports MDU-8-D card.

1, 2, 3, 4

HCPADP02

--

Accommodate both active cards and passive cards by dividing a slot into two half slots; where 1/2nd slot supports VOA, OADM1 and OADM4 cards.

1, 2, 3, 4

FPUADP01

--

Accommodates the FPU01 in the 2/3rd slot of HCPADP01.

1, 2, 3, 4

VOA

--

Supports eight ports in which eight hot pluggable VOA SFP modules can be inserted.

1, 2, 3, 4

PSCM

--

Splits the signal into N (N>1) parts in one direction and combines the N signals to produce one signal in other direction.

--

OFA-C-S26-FG/OFA-C-S23-FG

--

Provides a high output power of up to 26/23dBm.

--

OADM1 and OADM4

--

Adds and drops 1 and 4 channels at 100GHz spacing respectively.

1, 2, 3, 4

MDU-16-D

--

Adds and drop 16 DWDM channels with 100GHz spacing

1, 2, 3, 4

MDU-16CL-C-50G

--

16-channel multiplexer and demultiplexer active optical card.

2, 3, 4

NOTE: MDU-16CL-C-50G is a double slot card, hence this card cannot be installed on slot 1 of the chassis.

Slot distribution for TJ1600 Type-2SR

Slot distribution for TJ1600 Type-2SR

Card

Configuration

No. of Service Ports

Slot number

HCPSLine03

IntraCard TRANS/MUXPONDER

  • P1 to P4: 4 x STM64
  • Supports 10GE ports

1, 2

HCPSLine08

IntraCard TRANS/MUXPONDER

2xOTU2 + 8xSTM16/OTU1 or 16x GE/STM1/STM4

1, 2

HCPSLine12

 

10x10G TO 1xOTU4 MUXPONDER

1xOTU4 + 10xSTM64/OTU2/OTU2e/10GE/8GFC/12GFC

1, 2

 

Flexi 100G plus 10x10G to OTU4 Muxponder

P1: OTU4,P2:100GE

P4-P13: STM64/10GE LAN/OTU2/OTU2e/8GFC/12GFC

Flexi 2x40G plus 10x10G to OTU4 Muxponder

P1: OTU4, P2 & P3: 40GE

P4-P13: STM64/10GE LAN/OTU2/OTU2e/8GFC/12GFC

HCPSLine22

 

10x10G 1x100G TRIBUTARY AND CROSS-CONNECT

P1 to P10: STM64/10GE LAN/OTU2/OTU2e/8GFC

P11: OTU4

1, 2

10x10G FLEXI TRIBUTARY AND CROSS-CONNECT (gFEC and eFEC)

  • P3, P4, P5, P6, P8 and P10 STM1/4/16/64/10GE/1GE/1GFC/2GFC/8GFC
  • P1, P2, P7 and P9: OTU2/OTU2e/OTU1e/STM1/4/16/64/10GE/1GE/1GFC/2GFC/8GFC

HCPSLine24

1x100G Transponder OTU4 NP

1xOTU4/100GE (P4) + 1xOTU4 (P1)

1, 2

HCPSLine25

10x10G Transponder

  • Ports P1 to P10: OTU2/OTU2e
  • P11 to P20: STM-64/10GE/OTU2/OTU2e

1, 2

HCPSLine26

20x10G to 2 OTU4 Muxponder

P1: OTUC1/OTUC2

P2 - P21: STM64/10GE/OTU2/OTU2e/8GFC/12GFC

1, 2,

HCPSLine27

 

10X10G to OTU4 Muxponder + Flexi 100G to OTU4 Transponder

P1: OTUC1/OTUC2, P2: 100GE/OTU4

P4-P13: STM64/10GE/OTU2/OTU2e/8GFC/12GFC

1, 2

 

Two Flexi 100G to 2 OTU4 Transponder

P1: OTUC1/OTUC2, P2 & P3: 100GE/OTU4

HCPSLine28

 

1x100G Transponder OTU4 NP

1xOTU4 (P1) + 1xOTU4/100GE (P4)

1, 2

2X100G Transponder 100GE NP (100GE)

2xOTU4 (P1 and P4) + 2xOTU4/100GE (P2 and P3)

OFA-C-S20-VG

OFA-C-S20-LG

OFA-C-S20-HG

OFA-C-D20-VG

OFA-C-D20-LG

OFA-C-D20-HG

--

Amplifier ports and Monitor ports.

1, 2

OFA-C-S17-FG

OFA-C-D17-FG

--

Fixed Gain EDFA Single or Dual module design gives flat gain for all DWDM channels at the designed gain known as Designed Flat Gain (DFG). 17dBM gain modules.

1, 2

OFA-C-S20-LVG

OFA-C-D20-LVG

OFA-C-D20-MVG

--

S20-LVG: 20dBm single Ports Low Variable Gain DWDM amplifier

D20-LVG: 20dBm double port Low Variable Gain DWDM amplifier

D20-MVG: 20dBm dual port Mixed Variable Gain (Low Gain +High Gain) DWDM amplifier

1, 2

OFA-C-S26-FG/OFA-C-S23-FG

--

Provides a high output power of up to 26/23dBm.

--

ORA-C-450-FG

--

Enables longer reach spans for high loss networks.

--

HCPADP01

--

Accommodate both active and passive cards by dividing the slot into 2/3rd and 1/3rd slots.

1, 2

HCPADP02

--

Accommodate both active cards and passive cards by dividing a slot into two half slots; where 1/2nd slot supports VOA, OADM1 and OADM4 cards.

1, 2

MDU-8-D

--

Add and drop 8 DWDM channels with 100GHz spacing.

1, 2

MDU-16-D

--

Adds and drop 16 DWDM channels with 100GHz spacing

1, 2

MDU-96-C-50G

--

The MDU-96-C-50G 50GHz channel spaced DWDM multiplexer and demultiplexer with two 50 GHz Athermal Arrayed Waveguide Grating (AAWG) optical mux/demux modules, one for multiplexing and one for demultiplexing.

--

OADM1 and OADM4

--

Adds and drops 1 and 4 channels at 100GHz spacing respectively.

1, 2

OPM-C-4 and OPM-C-2

--

OPM-C-4 is a 4 port and OPM-C-2 is a two port card which measure optical power from either 4 or 2 monitoring input ports.

1, 2

VOA

--

Supports eight ports in which eight hot pluggable VOA SFP modules can be inserted.

1, 2

PSCM

--

Splits the signal into N (N>1) parts in one direction and combines the N signals to produce one signal in other direction.

--

MDU-40E-C-100G and MDU-40O-C-100G

--

100GHz channel with even spacing (192.00 to 195.90 THz) and with odd spacing (192.05 to 195.95 THz). It is a passive optical unit.

--

FPU01

--

Provides protection against the optical fiber line failures.

Pluggable in the HCPADP01 card that occupies 1/3rd slot.

See also

Card Population Rule

Slot Allotment

Using the Filler Panels