Perform the following steps to edit or modify the L2, GPON, and PDH ports:
NOTE: If user does not click Save Ports, the changes done will not be applied on that port.
An error message will get displayed if the editions on a port fails. This might happen due to reasons, some of which are listed as follows:
Parameter |
Description |
---|---|
Label |
Displays the port number selected in ci-si-pn format. This parameter cannot be edited. |
Type |
Allows you to edit the port type as DOT1Q, DEFAULT, DOT1Q_WITH_PRIO, DOT1Q_WITH_DSCP, DOT1AD, DOT1AD_WITH_DOT1Q, or COMBO. |
Acceptable Frame Policy |
Allows you to edit the acceptable frame policy applied to the selected port as Vlan Only or All. |
PVID |
Displays the port VLAN ID assigned to the port. |
Default Prio |
Allows you to edit the priority assigned to the port. Click on the value and select the desired value from the displayed options. |
Admin Status |
Allows you to edit the admin status of the port as 'Up' or 'Down'. |
Enable MPLS |
Allows you to enable or disable MPLS on the selected port by selecting/ un-selecting the check box. |
BPDU Tunneling |
Allows you to enable or disable BPDU Tunneling on the selected port by selecting/ un-selecting the check box. |
Auto Negotiation |
Allows you to enable or disable auto-negotiation on the selected port by selecting/ un-selecting the check box. |
Enable LLDP |
Allows you to enable or disable LLDP on the selected port by selecting/ un-selecting the check box. |
Enable SyncE |
Allows you to enable or disable syncE on the selected port by selecting/ un-selecting the check box. |
MTU(Bytes) |
Allows you to edit the maximum transmission unit on a port in bytes. |
Parameter |
Description |
---|---|
General |
|
Fec Status |
Enable or disable for forward error correction of frames egressing through the port. |
PON Physical Reach |
Edit the physical distance set between the OLT and the ONT device in the range 0 to 60 Km. All ONTs within the defined physical reach will be activated automatically. NOTE: Ensure the ONTs are installed in a way that there is a differential reach of less than 20 Km between two ONTs. |
Admin State |
Allows you to edit the admin status of the port as Activate or Deactivate. |
Onu Discovery Mode |
Edit the ONU discovery mode.
|
Ether Type |
Allows you to select the value from the options. |
Parameter |
Description |
---|---|
CEM Function Support |
Allows you to select CemEnable/CemDisable from drop down menu. |
Framing Type |
Allows you to select framed/unframed from the drop down menu. |
Framing Application |
Allows you to select framing application from the drop down menu. |
Port Channelization |
Allows you to select the port channelization to be used. |