Previous Topic

Next Topic

Book Contents

System specification

Type

Parameter

Value

Installation Rack

Installation rack type (in inch)

19"

Chassis installation rack height (RU)

8.3 RU (372 mm)

Air flow direction in the chassis

Right  to Left

Mechanical Specifications

 

Height

372 mm

Width

With Mount angles

483

Without Mount angles

440

Depth

Excluding Air Filter latch handle

258

Weight

Chassis with Mount angles, Backplane, and Air Filter Unit

11 KG

Electrical Specifications

 

Power Consumption

2500W

Input Voltage range

40V to 60V

Environmental Specifications

 

Operating temperature range

0 °C to 40 °C

below 0 °C is permissible and above 40 °C is permissible with probability less than 1%.

Relative humidity

95% RH

NOTE: If the HCPSLine26 and HCPSLine27 cards are used in the system then the system operating temperature range is derated to support from 0 °C to 40 °C.

A temperature of 50°C or -5°C is permissible but should not exceed the following:

- Duration: 96 continuous hours.

- Days: 15 days in one year.

- Occurrences: 15 times during a one-year period.

See ETSI EN 300 019-1-3 V2.1.2 and ETSI EN 300 019-2-3 V2.1.2 for Environmental Class 3.1.