The Power Filter Unit HCPPFU02 is a part of TJ1600-11 system.
There are two HCPPFU02 cards in each system to provide input source redundancy. An EMI filter is used to restrict conducted emissions. The filters have transient voltage suppressors to prevent voltage surges affecting the system.
Following are the functional features of the HCPPFU02:
Front panel
The following figure displays front panel of the HCPPFU02 card:
Operational specifications
Specification |
Range |
---|---|
Input Voltage Range |
-40V to -57.6V DC |
Reverse Polarity Protection |
Continuous |
Input Current |
|
Maximum operating Ambient Temperature |
-5°C to 55°C |
Output Voltage |
-40V to -57.6V DC |
Output Current |
65A |
Output Power |
|
Efficiency |
>90% Load when input is -48V DC |
Fuse |
80A Telecom fuse |
Under Voltage Protection |
|
Hold-up Time (Interruption) |
1.5ms at -53.2V and above |
Power Interface |
|
Protections |
|
Status Indication |
Power LED: Indicates presence of Output voltage (Green). |
Over Voltage Protection |
|