Previous Topic

Next Topic

Book Contents

Power Filter Unit

The Power Filter Unit HCPPFU02 is a part of TJ1600-11 system.

There are two HCPPFU02 cards in each system to provide input source redundancy. An EMI filter is used to restrict conducted emissions. The filters have transient voltage suppressors to prevent voltage surges affecting the system.

Following are the functional features of the HCPPFU02:

Front panel

The following figure displays front panel of the HCPPFU02 card:

TJ1600-11 HCPPFU02 - Front panel

Operational specifications

Operational Specifications of Power Filter Unit- HCPPFU02

Specification

Range

Input Voltage Range

-40V to -57.6V DC

Reverse Polarity Protection

Continuous

Input Current

  • 55A continuous at nominal voltage.
  • 65A at -40V Max, during normal operation.

Maximum operating Ambient Temperature

-5°C to 55°C

Output Voltage

-40V to -57.6V DC

Output Current

65A

Output Power

 

Efficiency

>90% Load when input is -48V DC

Fuse

80A Telecom fuse

Under Voltage Protection

  • Shutdown: -34V ± 2V
  • Recovery: -38V ± 2V

Hold-up Time (Interruption)

1.5ms at -53.2V and above

Power Interface

  • Input: One 3-pin Power Header
  • Output: One FCI Connector

Protections

  • Over Voltage
  • Under Voltage
  • Over Current

Status Indication

Power LED: Indicates presence of Output voltage (Green).

Over Voltage Protection

  • Shutdown: 61V ± 2V
  • Recovery: 58V ± 2V

See also

TJ1600-11

System specification

Fan Tray Unit

Slot allotment and bandwidth allocation

Cards overview

Interfaces