Fan Tray Unit

The Fan Tray Unit HCPFTU01 is used in TJ1600-11 chassis to cool the equipment. There are six fans present in the fan tray unit. It has two variants.

Functional features of fan tray unit (HCPFTU01) are:

Important considerations for FTU:

  1. The second variant of FTU should be used when system is populated with HCPXCC04.
  2. In case of single fan failure, the system works up to 40°C temperature. An Alarm is raised if any of the fans fails (the Fan tray is provided with six fans). The fan needs to be replaced, if an alarm exists on the FTU. If the alarm exists on the FTU and if the room temperature is below 40°C, the system works unless the second fan fails.
  3. Ensure that the fan tray unit is not removed before the replacement unit is available. Also ensure that the FTU replacement procedure be completed in 30 seconds time.
  4. Air filter is to be examined regularly at least once in 3 months. If appears dirty and clogged then to be cleaned or replaced. Cleaning to be done with vacuum cleaner.

Front panel

The front panel view of fan tray unit (HCPFTU01) is as follows.

TJ1600-11 HCPFTU01 - Front panel

Power specifications

TJ1600-11 HCPFTU01 - Power Specifications

Specification

 

Range

HCPFTU01 (Variant 1)

HCPFTU01 (Variant 2)

Input Voltage

-48V DC

-48V DC

Power consumption

200W

350W approximately

Operating Voltage Range

36-75V

36-60V

Max Input Current

0.77 A per fan

1.2 A per fan

Rated Speed

7000 RPM per fan

14900 RPM per fan

Operating Temperature

-40° to +70°C

-20° to +70°C

Storage Temperature

-40° to +75°C

-30° to +70°C