Previous Topic

Next Topic

Book Contents

OSCF-S and OSCF-D

Optical Supervisory Channel Filter (OSCF) adds and drops the supervisory channel wavelength primarily at the terminal, OADM, and intermediate line amplifier (ILA) sites where the OFA are used. OSC carries the management information related to the DWDM channels and enable to detect the fiber cuts and/or transmission degradation in the DWDM trunk.

Typical wavelengths used for supervisory channel are 1490nm and 1510 nm which are well outside the C-band DWDM transmission. A drop filter is required at the input of the DWDM amplifier and a add filter is required at the output of the DWDM amplifier.

This card either contains a single add and drop module (OSCF-S) or dual add and drop modules (OSCF-D), both of which can be used with OFA by plugging it in the card and no separate slot is required.

Front panel

The OSCF module is plugged into the OFA card at the center. OSCF-S and OSCF-D modules are shown in the figures below.

Front Panel View- OSPF-S

Front Panel View- OSPF-D

Power specifications

It is purely a passive card or unit.

Visual indicator details

There is no LED visual indication for this card or unit.

OSCF module types

Following types of OSCF are available.

Types of OSCF

Description

Model number

Optical supervisory channel (OSC) filters for 1510nm, two add ports and two drop ports

OSCF-D51

Optical supervisory channel (OSC) filters for 1510nm, one add port and one drop port

OSCF-S51

Functional description

Following is a schematic of the OSCF module connectivity.

8 Channel MDU connectivity OSCF

Typical specifications

Typical specification and functionalities of the OSCF modules are:

Typical Specifications of OSCF

Specification

Units

Values

Pass band for add and drop

nm

1510 +/- 10

Insertion Loss IN- EXP.OUT

dB

<0.65

Insertion Loss EXP.IN-OUT

dB

<0.65

Insertion Loss IN-DROP

dB

<0.75

Insertion Loss ADD -OUT

dB

<0.75