Viewing Provisioned MS-SP Ring

To view provisioned MS-SPRing, click Configuration > MS-SPRing in the navigation pane. The View MS-SPRing preview pane is displayed.

View MS-SPRing

MS-SP ring parameters

Parameter

Description

View

The configured MS-SP rings are displayed as links. The link, when clicked, displays the details of the MS-SP ring.

East Port

It is the east port of the ERP ring.

West Port

It is the west port of the ERP ring.

Ring Type

The type of ring-2-Fiber.

Ring Id

The ring identifier. All nodes within the same ring will have the same Ring Id. Acceptable values can be a set of alphanumeric characters.

Node ID

The identification number of the node. The value can range from 0 - 15. Two nodes cannot have the same node ID.

Extra Traffic Enable

Parameter to indicate if extra traffic can be used in the protection span when the protection span is not in use. Disable - Indicates extra traffic (low priority traffic) is not being carried in the protective span. Enable - Indicates low priority traffic is being carried in the protective span.

Ring WTR (Minutes)

The time to wait in minutes, before switching traffic back to work port from protect port, after the fault in work port has been rectified. Acceptable values range from 00 to 12 minutes.

Node State

The current state of the node- Switching State, bi-directional, Full pass through, Idle state, K-byte pass through, Wait To Restore.

Protection Switching Status- East Working Port

Displays whether the Protection switching is enabled on east working port.

Protection Switching Status- West Working Port

Displays whether the Protection switching is enabled on west working port.

Edit

Allows the user to edit the required ring.

Delete

Allows the user to delete the required ring.