The Fabric Debug Data option allows you to collect telecom bus dump information, AU-XC and TU-XC register dumps explicitly. On Fabric Debug Data preview pane, you can:
download the debug data to the local machine, and
clean up the data collected to take a fresh report
NOTE: This can be done for the master and secondary XCC cards separately.
Perform the steps given below to collect the debug data.
Click Maintenance > Diagnostics > Fabric Debug Data in the navigation pane. The Fabric Debug Data preview pane is displayed.
Select the Card Name from the list for which you want to collect the data.
Click Collect Data. Operation Successful message is displayed. Debug Data is present in the database.
Click Download Debug Data link to view or save the collected data.
Cleaning Up Debug Data Collected
Perform the steps given below to clean up the debug data already present in the database.
Click Maintenance > Diagnostics > Fabric Debug Data in the navigation pane.The Fabric Debug Data preview pane is displayed.
Click Clean Up Data. The stored data is cleared.
NOTE: The Clean UP Data button appears after collect debug data procedure is executed.