Previous Topic

Next Topic

Book Contents

Book Index

Collecting Debug Data of a Fabric Card

The Fabric Debug Data option allows you to collect telecom bus dump information, AU-XC and TU-XC register dumps explicitly. On Fabric Debug Data preview pane, you can:

NOTE: This can be done for the master and secondary XCC cards separately.

Perform the steps given below to collect the debug data.

  1. Click Maintenance > Diagnostics > Fabric Debug Data in the navigation pane. The Fabric Debug Data preview pane is displayed.

    Fabric Debug Data

  2. Select the Card Name from the list for which you want to collect the data.
  3. Click Collect Data. Operation Successful message is displayed. Debug Data is present in the database.
  4. Click Download Debug Data link to view or save the collected data.

Cleaning Up Debug Data Collected

Perform the steps given below to clean up the debug data already present in the database.

  1. Click Maintenance > Diagnostics > Fabric Debug Data in the navigation pane. The Fabric Debug Data preview pane is displayed.

    Clean up Fabric Debug Data

  2. Click Clean Up Data. The stored data is cleared.

    NOTE: The Clean UP Data button appears after collect debug data procedure is executed.

See Also

Diagnostics

Accessing OSPFv2 diagnostics data

Viewing System Information

Collecting Debug Data

Viewing HCPXCC04 Micro-SD Read/Write Profile

Collecting Micro-SD Statistics