To edit the Performance monitoring thresholds, set the corresponding Threshold (for 15-min and 1-Day) enabled in the Provision Interface - STM-n port preview pane.
Perform the steps given below to edit AU4/AU3.
The corresponding TCA Settings preview pane is displayed.
You can configure the following performance monitoring parameters:
Parameter |
Default Value |
Description |
|
---|---|---|---|
|
15 min |
1 day |
|
Threshold ES |
180 |
17280 |
Threshold for Errored Seconds. Acceptable values are 0 to 900 for 15 min duration and 0 to 86400 for 1 day duration. |
Threshold SES |
15 |
1440 |
Threshold for Errored Seconds. Acceptable values are 0 to 900 for 15 min duration and 0 to 86400 for 1 day duration. |
Threshold BBE/CV |
1100 |
105600 |
Threshold for Errored Seconds. Acceptable values are 0 to 65535 for 15 min duration and 0 to 6291360 for 1 day duration. |