Previous Topic

Next Topic

Book Contents

Create P2P/MEP circuits

Circuits can be created across multiple EMS and Partitions in NMS. Following types of circuits can be created:

To create P2P/MEP circuit, go to Configuration > Layer 1 > Create Circuit menu and click P2P/MEP Circuit. Create Circuit window is displayed in a new tab.

Create Circuit window

Create P2P/MEP Circuit Icons/Buttons

Number

Icons/Buttons

Operation

1

Mode

Displays the different mode: Work, Protect, Backup, and Protect Continue.

2

Refresh

Resets the parameters on the Create Circuit window. On clicking, a message All information on this page will be lost. Do you want to reset the page? will be displayed. Click OK to continue.

3

Pan icon

Allows the user to move the screen where circuit is displayed in all the directions.

4

Expand

Displays outgoing links of selected node with EMS and port details.

5

Delete

Deletes the selected node and work or protection group.

6

Show/Hide Labels

Displays the port details in the graphical view.

7

rearrange the graph

Re-arranges the graphical view displayed.

8

Show Alarms on selected path

Displays the alarms of the selected path.

9

Show Link Status

Displays the link status of the path.

10

Create Circuit

Creates a circuit in planned (pending) state in NMS database.

11

Create and Activate Circuit

Creates a circuit in NMS database as well as participative nodes in the circuit.

12

Close

Click the button to close the Create Circuit window.

13

Reversion

Allows you to provision the circuit in revertive and non-revertive mode and it is applicable only for protective circuits.

14

Properties

Displays the attributes and values of the selected node or the route details.

15

All Routes

Displays the routes existing on a circuit as WorkPath, ProtectPath. Click the desired path link to view the details of the Path under Properties section. The selected path will also get highlighted in pink in graphical view of the circuit.

NOTE: When the pan icon (Pan Option) is clicked, the icon shape is changed to the other pan icon (Pan Option Clicked). This icon allows the user to move the screen where circuit is displayed using the arrow button placed on the top left side of the page.

Attributes of Create Circuit

Attribute

Description

Common Circuit Info

Circuit Type

Allows you to select the type of circuit by clicking on the radio button:

  • P2P
  • MEP

Sub Type

Select the sub circuit type to be created from the drop down menu:

  • SDH/PDH/VCG
  • DWDM Circuit
  • OTN Circuit

Circuit name

Allows you to enter a name for the circuit. Acceptable values include characters A to Z, a to z, 0 to 9, _(underscore), -(hyphen), .(dot), &(ampersand), space.

Customer

Enter the name of the customer. The drop-down list will be displayed after entering the character in the field. If the drop-down list does not display any customer names, the user can create customer by clicking on the C link available against this field. The Create Customer page is displayed. For more information, refer to the Manage Customers section.

Capacity

Allows you to select the capacity for circuit creation. Values displayed in the drop down options depend on the Circuit Type selected by the user. This parameter is not displayed for DWDM circuit type.

  • VT1.5/VC11
  • VT2/VC12
  • STS1/VC3
  • STS3/VC4
  • STS12/VC4_4C
  • STS48/VC4_16C
  • STS192/VC4_64C
  • ODU0
  • ODU1
  • ODU2
  • ODU2E
  • ODU4
  • ODUflex

Direction

The direction is always Bi (Bi-directional).

Copies

Allows you to enter the number of circuit copies desired to create. This parameter is displayed for OTN and P2P circuit type.

Links

Enter the number of links required. This is applicable only for VCG circuits.

Higher Order

Select the check box if higher order circuit has to be created.

NOTE: Single Node Higher Order circuit can be discovered in the NMS by enabling the singleton support.

Enable CST

Select the check box to enable Client Signal Termination. This option is supported only for OTN circuits.

NOTE: Circuit creation involving CST is only supported for ODU1 and ODU2 capacities.

Time slot selection

By default the time slot selection is in 'Auto' for SDH/PDH/VCG circuits and 'Manual' for OTN circuits.

Class Of Service

Select the type of protection required from the drop down menu.

  • Unprotected: The circuit will have only one dedicated work path.
  • Protected: The circuit will have one work path and one protect path. In case of failure in work path, the traffic switches to protect path.
  • Diamond Service: The circuit will have three end to end paths which includes work, protect, and backup paths.

TL BandWidth Calculation

Select the check box to view the bandwidth on the Topological links, displayed after Route creation.

Frequency Selection

This parameter is displayed for DWDM Circuit Type only.

  • Manual: Select the radio button for manual selection of time slots. On selection, M link will get displayed against the Frequency parameter under Source Information.
  • Auto: Select the radio button for automatic selection of time slots.

Provisioning selection

This parameter is displayed for DWDM Circuit Type only.

  • Frequency: Frequency based selection.
  • Port: Port based selection.

Source/Destination Information

SrcTrafficType

DestTrafficType

Allows the user to select the source and destination traffic pattern from the options:

  • PDH
  • VCG
  • SONET/SDH
  • RADIO_PDH
  • RADIO_SDH/RADIO_SONET
  • ETH
  • OTN
  • FC

This parameter is not displayed for DWDM circuit type.

Node/IP

Select the Node check box and enter the IP Address of the Source/Destination node in IP text box provided; or enter the node name in IP text box. On entering a letter, the list pertaining to that letter will be displayed.

Port

On entering a valid IP, available ports will be displayed in the drop down options depending the Capacity selected. Select the desired port.

TimeSlot

  • If manual selection of time slots was selected, click the M link and select the desired time slots.
  • If auto selection of time slots was selected, the TimeSlot will be automatically selected.

Frequency

This parameter is applicable for DWDM circuit type only.

Add/Remove source protection

Click the link to add or remove protection to the Source port. This option is not applicable to VCG circuit types.

For adding protection, enter the Port and TimeSlot details.

Add/Remove destination protection

Click the link to add or remove protection to the Destination port. This option is not applicable to VCG circuit types.

For adding protection, enter the Port and TimeSlot details.

Start Route Creation

Click this button to initiate route creation after entering valid circuit creation details.

NOTE: The source and destination protection should be on the same nodes for Point-to Point (P2P) circuits whereas the source and destination protection can be on different nodes for Multi End Point (MEP) circuits.

Modifying the Timeslots

perform the following steps to modify the time slots of a circuit:

  1. Click Configuration > Layer 1 > Create Circuit menu and click P2P/MEP Circuit. The Create Circuit window is displayed in a new browser window.
  2. Enter the details for Create Circuit, Source information and Destination Information.
  3. Click Start Route Creation. The graphical view is shown at the right side of the window.
  4. The user has to manually select the path from source to destination. A table with all outgoing topological links from source node is displayed. It can be seen by selecting the node (source or any other node) and then clicking on "Expand" button. The table contains topological links outgoing from the selected/highlighted node, with port details.
  5. Double-click the desired topological link in the table to select the path.
  6. For creating protect path, select the class of service as "Protected".
  7. Select a node for creating the protect path.
  8. Click WorkPath to see the work path. The work path is highlighted. The Properties section displays the details about the object selected in All Routes section.
  9. Click ProtectPath to see the protect path. The protect path is highlighted. The Properties section displays the details about the object selected in All Routes section.
  10. Select the trunk from the create circuit window to modify the time slots.
  11. Select the desired time slot from the Properties window after clicking the R button.
  12. Select the Create option. The circuit will be in planned state in NMS and it will be stored in the NMS database OR Select the Create & Activate option. The cross connects will be provisioned on the node as well as on NMS.

See also

Circuits

Supported Protection Schemes

Create Singleton circuits

Single Homing Ring Splitting

Dual Homing Ring Splitting

Create circuits using Diamond services

Switching of paths in Diamond circuits

Create circuits from Topology View

Discover circuits

Discover GMPLS circuits

Manage Circuits