Add ONT

Perform the following steps to add ONT:

  1. Go to Configuration > Access menu and click Manage ONTs option. Manage ONTs page is displayed.
  2. Click (Add ONT). The Add ONT window is displayed.

    Add ONT window

  3. To add vendor details,
    1. Click on button on Add ONT window. The options to enter vendor details will be displayed.

      Adding Vendor in Add ONT window

    2. Enter Vendor Name and Vendor Id in the respective text boxes provided.

      The vendor Id is the first 8 digits of serial number of ONT.

    3. Click Submit. The vendor name will be added in the drop-down options for selecting Vendor Name.
  4. To delete vendor details,
    1. Click on button on Add ONT window. Select the option from down menu of the vendor name to be deleted.

      Deleting Vendor Name in Add ONT window

    2. Click Delete. The vendor name will be deleted from the drop down menu option.
  5. Enter the rest of the ONT details by referring to the table Add ONT parameters.
  6. Do one of the following:

Add ONT parameters

Parameter

Description

Add Vendor

Click on the button to add the vendor.

Delete Vendor

Click on the button to delete the vendor.

Node: IP

Enter the node name or select the check box and enter IP address of the node to which the ONT is connected.

Pon Port

Select the PON port to which the ONT is connected.

Vendor Name

Select the vendor name of the ONT from drop down option.

Serial No

Enter the unique serial number of the ONT provided by the vendor.

Mac Address

Enter the MAC address of the ONT.

Close on Success

Select the check box to close the Add ONT window automatically.

NOTE: User has to enter either Serial No or MAC address of the ONT.

Replacing Faulty ONT with New ONT

Follow the procedure to replace the faulty ONT without reconfiguring the services for new ONT.

  1. Create and activate ELINE service between Ethernet port of control card in TJ1400 and ONTGETH port of ONT.
  2. De-activate the ELINE service, the status of the service will go to pending state (corresponding L2 service and connection will be deleted from node).
  3. Disable and delete the ONT, replace faulty ONT with the new ONT.
  4. Activate the service. The service and connection will be resumed on node with new ONT.

See also

Manage ONTs

Delete ONT

Activate/Enable ONT

Deactivate/Disable ONT

Configure ONTG

ONT maintenance

Synchronize ONT

Change Serial Number of ONT

Filter ONT

View ONT Alarms

Generate ONT Summary Report

Group ONTs

ONT Ethernet Port Loopback

Editing ONT Ethernet Ports Configuration

Right Click options supported on ONT