Optical power monitoring per channel is required in the DWDM system in order to control the transmission performance. By measuring power using OPM and selectively pre-emphasizing each transmitter output power using variable optical attenuation OSNR at the end of the link can be optimized. OPM-C-4 is a 4 port and OPM-C-2 is a two port card which measure optical power from either 4 or 2 monitoring input ports such as OFA in the C band at 50GHz, respectively. Each card is half slot and a total of two such cards can be used in one slot with an optical adaptor card.
The following figure shows the front panel of OPM-C-4 and OPM-C-2 cards with adaptor card:
Specification |
Range |
---|---|
Input Voltage |
-48V DC |
Power consumption (max) |
5W |
The schematic diagram of the OPM-C-4 and OPM-C-2 cards is as follows:
The input ports can be connected to any optical monitoring ports such as the monitoring ports of the OFA cards for optical power read out up to 80 Channels at 50GHz intervals.
Typical specifications and functionalities of the OPM-C-4 and OPM-C-2 cards are as follows:
The following table summarizes the different parameters and its typical values:
PARAMETER |
UNITS |
SPECIFICATION |
||
Min |
Typical |
Max |
||
Minimum channel spacing |
GHz |
50 |
100 |
- |
Spectral range |
nm |
1529 |
- |
1565 |
Absolute wavelength accuracy |
pm |
- |
- |
+/-100 |
Input power range |
dBm |
-35 |
- |
+6 |
Power sensitivity |
dBm/0.1nm |
-45 |
- |
- |
Absolute power accuracy |
dB |
- |
- |
+/-1.0 |
Absolute signal total power accuracy |
dB |
- |
- |
+/-1.0 |
Power resolution |
dB |
- |
0.1 |
- |
OSNR measurement accuracy |
dB |
- |
- |
±1 @ OSNR< 20dB |
Measurement time |
ms |
- |
- |
<1 |
Power consumption |
W |
- |
3 |
5 |