HCPSLine08

HCPSLine08 card supports 2 XFP and 16 SFP interfaces. The card is supported in TJ1600 Type-11SR, TJ1600 Type-6SR and TJ1600 Type-2SR chassis.

The mode(s) supported with HCPXCC03 in TJ1600 Type-11SR chassis include:

The mode(s) supported with HCPXCC04 in TJ1600 Type-11SR chassis include:

The mode(s) supported with OSMC01 card in TJ1600 Type-11SR and TJ1600 Type-6SR chassis include:

IntraCard TRANS/MUXPONDER -> P1 and P2: OTU2 + P3 to P10: STM-16/OTU1 or P3 to P18: STM-1/4/1GE

The mode(s) supported with OAMC card in TJ1600 Type-2SR chassis include:

IntraCard TRANS/MUXPONDER -> P1 and P2: OTU2 + P3 to P10: STM-16/OTU1 or P3 to P18: STM-1/4/1GE

NOTE 1: In OTN FlexiCard or IntraCard TRANS/MUXPONDER mode, if P3 to P10 ports are configured as STM-16, then remaining ports (P11 to P18) cannot be used.

NOTE 2: With HCPXCC04, fresh card configuration is not supported for SDH GATEWAY Card mode.

One-to-One Port Mapping

Front panel

Following figure shows the front panel view of HCPSLine08 card:

Front Panel View- HCPSLine03 Card

Power specifications

Power specifications- HCPSLine08

Specification

Range

Input Voltage

-48V DC

Power consumption

100W

Visual indicator details

The visual indicators on the HCPSLine08 card include two LEDs, the ACTIVE and the STATUS LEDs.

Possible LED status and their significance- HCPSLine08

Card State

Status LED

Active LED

Card initialization: State before the card initialize is complete on card insertion.

Amber (Steady)

Amber (Steady)

Card in service: Initialization complete and card in service.

Green (Steady)

Green (Steady)

Card mis-match: Node has already configured the slot with some other card.

Amber

Amber

Card failed during boot up.

Red

Amber

Card failed while in-service.

Red

Green

Improper jack in of the card

Green (Blinking)

Green (Blinking)

Hard Reset: All devices reset, FPGAs cleared and reprogrammed. Goes to initializing state next.

Amber

Amber

Soft Reset: Software is restarted, devices are reinitialized with provisioning. Goes to initializing state next.

Green

Green

Early Ejector LED status: One ejector is removed (contains one ejector switch in right).

OFF

Amber

SFP/XFP port visual indications

SFP/XFP Port Transmitter (Tx) and Receiver (Rx) LED Status- HCPSLine08

State

Rx LED

Tx LED

SFP/XFP present (Laser on) with Rx LOS.

Amber

Green

SFP/XFP present (Laser off) with Rx LOS.

Amber

Off

SFP/XFP present (Laser on) with no Rx LOS.

Green

Green

SFP/XFP present (Laser off) with no Rx LOS.

Green

Off

Card failed while in-service.

Red

Green

SFP/XFP missing (LOS detected), Laser On (attempted).

Amber

Green

SFP/XFP missing (LOS masked since XFP missing and set to Admin_down), Laser Off (attempted).

Amber

Off

SFP/XFP failed (whether provisioned, unprovisioned, LOS or no LOS).

Red

Red

LASER Types

The LASER types supported are:

Optical Safety Warning OPTICAL SAFETY: Do not stare or look directly into the optical connector output beam, as this can cause irreparable damage to your eyes and even loss of eye sight.

Functional Description

HCPSLine08 card processes the received GE/STM-16/STM-64 frame for all alarms and performance monitoring signals.

HCPSLine08 card supports the following functional features:

See also

Line Cards

HCPSLine01

HCPULine01

HCPSLine03

HCPSLine12

HCPSLine20

HCPSLine22