Create Dual Homed ELINE service

The type of ELINE service connecting the dual homed node with the primary node and the backup node, is referred to as dual homed service.

NOTE: Dual Homing for .1q/.1ad services is supported in this release. The user can create one end or both end of dual homed services. In case of .1q/.1ad service, backup node can only be on the same ring of which primary node is a part. While adding backup node, remaining nodes of the same ring will only be displayed to the user.

Perform the following steps to create an ELINE dual homed service:

  1. Go to Configuration > Layer 2 > Services menu and click Complete Services option. The Complete Services page is displayed.
  2. Click on . A series of new windows will be displayed for step-by step creation of a service.

Refer End Points parameters table in the topic Create MPLS-TP service for description of parameters on End Points page.

The PseudoWires page of Create Service provides the options for selection of pseudowire path manually or automatic path detection and MA configuration.

To find pseudowire path automatically,

  1. First enable Find Path button by selecting the Auto Path Icon (Auto Path) check box. The check box will be selected by default.
  2. Click Find Path. A success message is displayed. Path is found successfully.
  3. Click OK and select a pseudowire endpoints (Sw1--Sw2) to view its path under the View tab.

    Graphical representation of the pseudowire detected automatically is displayed under the View tab as shown in the following figure. Details of work and protect path, excluded switches, and excluded tunnels are available under Details column:

    Create Service- Step 4 (PseudoWire- Auto Path)

Refer General Attributes parameters table in the topic Create MPLS-TP service for description of parameters on General attributes page.

NOTE: When finding the pseudowire path automatically, the user is provided an option to exclude switches/tunnels. Select Excluded Switches and Excluded Tunnels tab. Click Add button and select the desired nodes and/links. Click Exclude Nodes or Exclude Links followed by Done. Remove button can be used to delete the added data. Select Find Path. Pseudowire path is calculated once again, excluding the selected switches/tunnels in the path.

To find pseudowire path manually,

  1. Un-check the Auto Path Icon (Auto Path) check box and then select the endpoints (Sw1--Sw2). The Manual Path button is displayed under the View tab.
  2. Click Manual Path. The topology selection window is displayed.
  3. Select the path/link connecting the two selected end points (highlighted in black) and click Add Work. The work path is added and represented in blue solid line.

    PseudoWire selection- Adding Work Path

  4. To add protection path, select the path/link connecting the selected two end points (highlighted in black) and click Add Protect. The protect path is added and represented in blue dashed line.

    PseudoWire selection- Adding Protect Path

  5. Click Done. In case path addition fails, the partial link selection will be reset.

    Graphical representation of the pseudowire added is displayed on the PseudoWires page under View tab along with work and protect path details under Details column as shown in the following figure:

    Create Dual Homed Service- Step 4 (PseudoWires- Manual Path)

  6. Click Next.

    NOTE: An additional PW Status Info page will be displayed if OAM was selected as 'Pw Status' on General Attributes page. For more information refer to Step 4: PW Status Info in the topic Create MPLS-TP service with PWSM.

On Advance Configuration window, Storm Control Configuration is performed. Select the Enable Broadcast/MultiCast Stormcontrol check box if desired and then enter the BroadCast/Multicast Stormcontrol value in Mbps in the text box displayed. Click Next to view the summary of the service.

Create Dual Homed Service- Step 5 (Advance Configuration)

On Summary page of Create Service, the end points with the connecting pseudowire is displayed as shown in the following figure:

Create Dual Homed Service- Step 6 (Summary)

  1. From the drop down menu, select Create to create the service or Create and Activate to create and activate the service as desired.
  2. Click Finish. Service creation command sent successfully message is displayed.
  3. Click OK. The status of the service can be checked in Complete Services page.

See also

Services

Create .1q/.1ad service

Create GPON service

Create Singleton service

Create MPLS-TP service

Create bulk services

Create CEM service

Create MPLS-TP service with PWSM

Create MPLS-TP ELINE Dual Homed services over a single switch

Create Dual Homed ELAN service

Create Dual Homed CEM service

Create ELAN services with full mesh

Create ELAN services with Hub and Spoke

Verify ILL provisioning (ELINE/ELAN) from NMS

Create services with L1 and CE/MacBridge cards

Activate service

Deactivate service

Delete service

Toggle Service non-NMS to NMS

Create service using selected services

View service bandwidth consumption

View service alarms

Service performance management

Refresh current view

Advanced filter options

Summary report of services

Manage services

Service Y1731 Management