The following figure shows setup for ILL provisioning:
To verify ILL provisioning (ELINE/ELAN) from NMS,
Jack-in L1 card in the system.
Create circuit from NMS between the VCG ports of switch B and switch C. Refer Create P2P circuit for the creation of circuits procedure.
Ensure that circuit is active VCG to VCG TL is shown in Topology View.
Create MPLS tunnel between switch A and switch B. Refer Create Tunnels.
Try to Create MPLS service between switch A and switch B, with switch A UNI as ETH port for verifying traffic and switch B UNI as the VCG port going to L1 card. Refer Create services with L1 and CE/MacBridge cards
After creation of service, verify traffic over the same. Refer Create MPLS-TP service for creating the service between switch A to switch B.
De-activate/Activate services and verify the VCG port mapped to L1 card should be available as UNI port while provisioning.