Verify ILL provisioning (ELINE/ELAN) from NMS

The following figure shows setup for ILL provisioning:

ILL Provisioning

To verify ILL provisioning (ELINE/ELAN) from NMS,

  1. Jack-in L1 card in the system.
  2. Create circuit from NMS between the VCG ports of switch B and switch C. Refer Create P2P circuit for the creation of circuits procedure.
  3. Ensure that circuit is active VCG to VCG TL is shown in Topology View.
  4. Create MPLS tunnel between switch A and switch B. Refer Create Tunnels.
  5. Try to Create MPLS service between switch A and switch B, with switch A UNI as ETH port for verifying traffic and switch B UNI as the VCG port going to L1 card. Refer Create services with L1 and CE/MacBridge cards
  6. After creation of service, verify traffic over the same. Refer Create MPLS-TP service for creating the service between switch A to switch B.
  7. De-activate/Activate services and verify the VCG port mapped to L1 card should be available as UNI port while provisioning.

See also

Services

Create .1q/.1ad service

Create GPON service

Create Singleton service

Create MPLS-TP service

Create bulk services

Create CEM service

Create MPLS-TP service with PWSM

Create Dual Homed ELINE service

Create MPLS-TP ELINE Dual Homed services over a single switch

Create Dual Homed ELAN service

Create Dual Homed CEM service

Create ELAN services with full mesh

Create ELAN services with Hub and Spoke

Create services with L1 and CE/MacBridge cards

Activate service

Deactivate service

Delete service

Toggle Service non-NMS to NMS

Create service using selected services

View service bandwidth consumption

View service alarms

Service performance management

Refresh current view

Advanced filter options

Summary report of services

Manage services

Service Y1731 Management